10. Settings
10.3 Restoring the factory settings

How to restore the factory settingsfor the display function and the color temperature ?

1. Press MENU to activate the Toolbar
2. Press to select the Settings item
3. Press to Pull down the Settings menu
4. Use or to select Factory reset (image 10-7)
5. Press ENTER
Thedisplay function and color temperature are adapted and the corresponding LUT is loaded.
Image10-7
Factorysettings are “dark room” settings meaning they do not take account of environmental co nditions (am-
bient light, glare,...).
10.4 Black and white selection

Build up of the Luminance signal Y

Thecolor signals on the 5 BNC connectors can be chosen to be converted to a luminance signal Yin several ways. Thecontribution
tothe luminance sig nal can be chosen to be done by one or more color components.
Additionally,switching color components may accentuate some details and that way emphasize a part of the projected image.
Selection Projectedimage Comment Image
RGBto RGB color -image 10-8
GtoY black& wh ite Greenis replaced by white (bright) image10-11
RGBto Y black & white -image 10-9
RtoY black& white Red is replaced by white (bright) image10-10
BtoY black& white Blue is replaced by white (bright) image10-12
RBGto Y black & white bars are repositioned image10-13
GRB to Y black& white bars are repositioned -
GBR to Y black& white bars are repositioned -
BRGto Y black & white bars are repositioned -
BGR to Y black& white bars are repositioned -