4.8.2 Displaying and Programming addresses into the RCU

Displaying the Projector Address on the Screen.

1. Press the Address key (recessed key on the RCU) with a pencil.
The projector’s address will be displayed in a ’Textbox’
To continue using the RCU with that specific address, it is necessary to enter the same address with the
digitbuttons (add ress between 0 and 9) within 5 seconds after pushing the address key. For example : if the
Addresskey displays projector address 003, th en press "3" digit button on the RCU to set the RCU’sad dress
tomatch the projector ’saddress. Donot press 0–0–3 . Thiswill address the remote control to ’0’ and con trol
allprojectors in the room. Ifthe address is not entered within 5 seconds, the RCU returns to its default address
(zeroad dress) and controls then all projectors in the room.
Address0 (or 1) should alw ays allow communication with the projector since it is a common address.

Displaying the Projector Address in Standby

1. Press the Address key (recessed key on the RCU) with a pencil.
All the LED’son top of th e projector go out.
The LED3 starts blinking green. The number of blinking stands for the number of hundreds. After that LED2 starts blinking for
the number ofte ns. Finally LED3 starts blinking for the number of units. If the blinking is done, the original status of the LEDs
restored.
4.9 Controlling the projector

Input Selection

Keyin the corresponding slot number with the digit keys on the RCU. The selected source will be displayed.

Input Selection with alternative custom file(slot extension)

Itis possible to select the same input but with another settings (another custom file will be loaded).
Howtodoit:
1. Pressfirst 0on theRCU. The Slot extension menu will be displayed.
2. Enterthe tw o digits. First digit is custom file sequence and the second digit is the input. E.g. 33, the third custom file will be
loaded for source 3. If it does not exist, it will be created.
Thesame input can be loaded with 9 different input sources. E.g. for source 3, the input can be from 13 over 23 to 93.
Image4-10 Image4-11

Picture Controls

When an image control is pressed, a text box with a bar scale, icon and function name of the control, e.g. ’brightness...’ appears
onthe screen (only if Textbox in the Display Setup menu is ON). The length of the bar scale and the value of the numeric indication
indicatethe current memorize d setting fort hisso urce. The bar scale changes as the arrows on the RCU are pressed or the + or -
buttons on the local keypad.
The picture settings are saved in the image file.
Image4-12
R5976815 RLM G5I PERFORMER 02/06/2006 39