FLR110D48F, FLR140D60F Remove Bleed Port to attach pressure guage, Pressure Gauge MIS-1660
Models:
FH110D60F
FLR085D36F
FC085D36F
FLF085D36F
FLF110D48F
FLR110D60F
FLF110D60F
FLR110D48F
FH085D36F
FH110D48F
FLR140D60F
1
23
42
42
Download
42 pages
59.71 Kb
20
21
22
23
24
25
26
27
<
>
Specifications
Install
NO. 2 FUEL OIL EFFICIENCY CHART
Dimension
Maintenance
Wiring
Pushing the Reset button will
Typical Unit Setup Flf Unit Shown
Gun Assembly Adjustment
Short Form Adjustment Procedure
Page 23
Image 23
FIGURE 9
PRESSURE GAUGE CONNECTION TO BLEED PORT
Remove Bleed Port to attach pressure guage.
Pressure Gauge
MIS-1660
Manual
2100-422M
Page
23 of 42
Page 22
Page 24
Page 23
Image 23
Page 22
Page 24
Contents
FLF085D36F FLF110D48F FLF110D60F
OIL FURNACE INSTALLATION INSTRUCTIONS
FOR YOUR SAFETY
FH085D36F FH110D48F FH110D60F
CONTENTS
FOR MORE INFORMATION, CONTACT THESE PUBLISHERS
GETTING OTHER INFORMATION and PUBLICATIONS
LOCATING THE FURNACE
INSTALLATION and OPERATING INSTRUCTIONS
EQUIPMENT SELECTION
TOP VIEW
FLF/FLR 085, 110 AND 140 SPECIFICATION SHEET
FIGURE FLF/R MODELS DIMENSIONS TABLE
FLF/R MODELS DIMENSIONS INCHES
LEFT SIDE VIEW
FH085 AND FH110 SUPPLY SPECIFICATION SHEET
FIGURE FH MODELS DIMENSIONS
TOP VIEW
FRONT VIEW
COUNTERFLOW SPECIFICATION SHEET
TOP VIEW
LEFT SIDE VIEW
DUCT WORK
INSTALLING THE FURNACE
INSTALLING A COOLING UNIT
TABLE ELECTRICAL DATA
WIRING
FACTORY WIRING
FIELD WIRING
TYPICAL UNIT SETUP FLF UNIT SHOWN
needed venting system
INSTALLER NOTE
standards for installing
Follow all appropriate
Vent Cap 2 Cap 2 Fill Pipe
Manual
BECKETT “CLEANCUT” OIL PUMP
BECKETT SOLID STATE IGNITER
GENISYS 7505 PRIMARY CONTROL
BECKETT GENISYS
PRIMARY OPERATIONAL GUIDE
Button Click
Pushing the Reset button will
On Continuously
Flashing
PRIMING THE PUMP
RESETTING FROM RESTRICTED LOCKOUT
THERMOSTAT CONNECTIONS HEATING BLOWER OFF DELAY
TABLE FURNACE DATA
BURNER SETUP AND ADJUSTMENT PROCEDURES
3.COMBUSTION DIAGNOSIS
2.COMBUSTION ADJUSTMENT STEPS
1.PREPARATION STEPS
2.CHECK DRAFT
SHORT FORM ADJUSTMENT PROCEDURE
1.SERVICE AND CLEAN BURNER
4.FINAL CHECKS
Percent CO2 in Flue Gas
Air Settings
High
Bacharach Smoke Number
FIGURE PRESSURE GAUGE CONNECTION TO BLEED PORT
Remove Bleed Port to attach pressure guage
Pressure Gauge MIS-1660
Manual
NO. 2 FUEL OIL EFFICIENCY CHART
TABLE 7 - RECOMMENDED START-UPSETTINGS
NET STACK TEMP. DEGREES F
FIGURE 10B ELECTRODE ADJUSTMENTS - NX BURNERS
GUN ASSEMBLY ADJUSTMENT
REMOVING GUN ASSEMBLY
FIGURE 10A ELECTRODE ADJUSTMENTS - AFG BURNERS
AFG BURNER COMBUSTION AIR BOOT ASSEMBLY
TABLE SQUARE FEET REQUIRED TO
APPLIANCES LOCATED IN CONFINED SPACES
FIGURE APPLIANCES LOCATED IN CONFINED SPACES
ALL AIR FROM INSIDE THE BUILDING
ALL AIR FROM OUTDOORS
TABLE MINIMUM VENTILATION OPENINGS
ALL VENTILATION AIR FROM OUTDOORS
FIGURE APPLIANCES LOCATED IN CONFINED SPACES
FIGURE APPLIANCES LOCATED IN CONFINED SPACES
VERTICAL VENTING
LOUVERS AND GRILLES
VENTING OPTIONS
THERMOSTAT
2100-422M
TEMPERATURE RISE RANGES, LIMIT CONTROL SETTINGS
AND HEATING BLOWER SPEEDS
Manual
2 screws
AIR FILTERS
Optional Filter Box FC Unit 19 1/4 70 5/16
Filter
STEP SLIDE FILTER OUT TOWARDS BLOWER DOOR
INSPECT AIR FILTER
MAINTENANCE
SERVICE HINTS
LUBRICATION
INSTRUCTIONS
DANGER
BURNER REMOVAL
REMOVAL INSTRUCTIONS
DANGER
BURNER AND COMB. CHAMBER MOUNTING SYSTEM
CARE OF FINISH
CLEANING OF THE HEAT EXCHANGER
COMMON CAUSES OF TROUBLE
BLOWER SYSTEM RESISTANCE CHARTS
CHART FLR140D60F DATA
DANGER
COND
THERMOSTAT
UNIT
THERMOSTAT
WIRING DIAGRAM
UNIT
4047-119E
THERMOSTAT
WIRING DIAGRAM
UNIT
4047-120D