Bard FC085D36F, FLR140D60F, FLR110D48F Factory Wiring, Field Wiring, Table Electrical Data

Models: FH110D60F FLR085D36F FC085D36F FLF085D36F FLF110D48F FLR110D60F FLF110D60F FLR110D48F FH085D36F FH110D48F FLR140D60F

1 42
Download 42 pages 59.71 Kb
Page 9
Image 9
WIRING

WIRING

FACTORY WIRING

All units are fully factory wired. Multispeed blowers are factory wired on high speed for cooling/manual fan operation. Heating speeds are wired for the largest input and may need lower speed for field installed low input nozzle. If replacement wire is necessary, use 105 degrees C minimum. See electrical data, Table 3.

FIELD WIRING

All wiring must conform to the National Electrical Code and all local codes. A separate fuse or breaker should be used for the furnace.

TABLE 3

ELECTRICAL DATA

 

 

 

 

 

 

 

 

Max. Time

 

 

 

Blower Motor

Burner Motor

Minimum

Delay Fuse

 

 

 

 

 

 

 

 

 

Total

HP

FLA

HP

FLA

Circuit

or HACR

Model

Volts-HZ-PH

Amps

Ampacity

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

FH085D36F

115-60-1

7.3

1/3

5.6

1/7

1.7

9

15

 

 

 

 

 

 

 

 

 

FH110D48F

115-60-1

12.2

1/2

10.5

1/7

1.7

15

20

 

 

 

 

 

 

 

 

 

FH110D60F

115-60-1

14.2

3/4

12.5

1/7

1.7

18

20

 

 

 

 

 

 

 

 

 

FLF085D36F

115-60-1

7.3

1/3

5.6

1/7

1.7

9

15

 

 

 

 

 

 

 

 

 

FLR085D36F

115-60-1

7.3

1/3

5.6

1/7

1.7

9

15

 

 

 

 

 

 

 

 

 

FLF110D48F

115-60-1

12.2

1/2

10.5

1/7

1.7

15

20

 

 

 

 

 

 

 

 

 

FLR110D48F

115-60-1

12.2

1/2

10.5

1/7

1.7

15

20

 

 

 

 

 

 

 

 

 

FLF110D60F

115-60-1

14.2

3/4

12.5

1/7

1.7

18

20

 

 

 

 

 

 

 

 

 

FLR110D60F

115-60-1

14.2

3/4

12.5

1/7

1.7

18

20

 

 

 

 

 

 

 

 

 

FLR140D60F

115-60-1

14.2

3/4

12.5

1/7

1.7

18

20

 

 

 

 

 

 

 

 

 

FC085D36F

115-60-1

7.3

1/3

5.6

1/7

1.7

9

15

 

 

 

 

 

 

 

 

 

Manual

2100-422M

Page

9 of 42

Page 9
Image 9
Bard FC085D36F, FLR140D60F, FLR110D48F, FLR085D36F, FH110D60F warranty Factory Wiring, Field Wiring, Table Electrical Data