Bard FH110D60F, FLR140D60F Danger, Burner And Comb. Chamber Mounting System, Removal Instructions

Models: FH110D60F FLR085D36F FC085D36F FLF085D36F FLF110D48F FLR110D60F FLF110D60F FLR110D48F FH085D36F FH110D48F FLR140D60F

1 42
Download 42 pages 59.71 Kb
Page 36
Image 36
!DANGER

TO REMOVE BURNER ONLY

Disconnect fuel line, power cord and wires from T, T on primary control. Loosen (3) 1/4 inch bolts securing burner mounting flange. Twist burner counterclockwise and pull straight back away from the furnace. (See Figure 19.)

TO REMOVE THE ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM

Disconnect fuel line, power cord and wires from T, T on primary control. Remove (6) 5/16 inch bolts from around front plate. Next remove (2) 5/16 inch nuts from upper right and left hand corners of the front plate. Pull entire assembly straight back away from furnace. BE CAREFUL NOT TO TIP ASSEMBLY UP OR DOWN AS IT MAY DAMAGE THE COMBUSTION CHAMBER. (See Figure 20.)

FIGURE 20

REMOVAL OF ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM

!DANGER

*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.

STEP 3:

REMOVE (2) NUTS

IN THE TOP LEFT

AND RIGHT CORNERS

OF BURNER PLATE.

STEP 4:

PULL BURNER ASSEMBLY STRAIGHT OUT TO PREVENT DAMAGE TO CHAMBER DURING REMOVAL.

BURNER AND COMB. CHAMBER

MOUNTING SYSTEM

REMOVAL INSTRUCTIONS

CHAMBER

BURNER

PLATE

STEP 2:

REMOVE (6) BOLTS

AROUND PERIMETER OF BURNER PLATE

STEP 1:

DISCONNECT "T-T" WIRES,

POWER CONNECTIONS, AIR

BOOT (OPTIONAL) AND OIL

LINES TO BURNER.

MIS-1837 A

 

Manual

2100-422M

Page

36 of 42

Page 36
Image 36