TO REMOVE BURNER ONLY
Disconnect fuel line, power cord and wires from T, T on primary control. Loosen (3) 1/4 inch bolts securing burner mounting flange. Twist burner counterclockwise and pull straight back away from the furnace. (See Figure 19.)
TO REMOVE THE ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM
Disconnect fuel line, power cord and wires from T, T on primary control. Remove (6) 5/16 inch bolts from around front plate. Next remove (2) 5/16 inch nuts from upper right and left hand corners of the front plate. Pull entire assembly straight back away from furnace. BE CAREFUL NOT TO TIP ASSEMBLY UP OR DOWN AS IT MAY DAMAGE THE COMBUSTION CHAMBER. (See Figure 20.)
FIGURE 20
REMOVAL OF ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM
!DANGER
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
STEP 3:
REMOVE (2) NUTS
IN THE TOP LEFT
AND RIGHT CORNERS
OF BURNER PLATE.
STEP 4:
PULL BURNER ASSEMBLY STRAIGHT OUT TO PREVENT DAMAGE TO CHAMBER DURING REMOVAL.
BURNER AND COMB. CHAMBER
MOUNTING SYSTEM
REMOVAL INSTRUCTIONS
CHAMBER
BURNER
PLATE
STEP 2:
REMOVE (6) BOLTS
AROUND PERIMETER OF BURNER PLATE
STEP 1:
DISCONNECT
POWER CONNECTIONS, AIR
BOOT (OPTIONAL) AND OIL
LINES TO BURNER. | |
|