Baumatic BC190.2TCSS manual Gas adjustment Conversion to LPG for the hob top

Models: BC190.2TCSS

1 44
Download 44 pages 35.41 Kb
Page 32
Image 32

Gas adjustment (Conversion to LPG for the hob top)

All work must be carried out by a GASSAFE registered engineer.

IMPORTANT: Always isolate the cooker from the electricity supply before changing the injectors and/or adjusting the minimum flow of the burners.

o Remove the pan-stands, burners and flame spreaders.

oUnscrew the injector and replace it with the stipulated injector for the new gas supply (see table below).

Burner

Types

Pressure

Injector

Gas

 

Power

 

of gas

(mbar)

Marking

consumption

(kW)

 

 

 

(1/100

g/h

 

l/h

Max.

Min.

 

 

 

mm)

 

 

 

 

 

Auxiliary

Natural

20

72

-

 

95

1.00

0.48

 

(G20)

 

 

 

 

 

 

 

 

Butane

30

50

73

 

-

 

 

 

(G30)

 

 

 

 

 

 

 

 

Propane

37

50

71

 

-

 

 

 

(G31)

 

 

 

 

 

 

 

Semi-

Natural

20

97

-

 

167

1.75

0.60

rapid

(G20)

 

 

 

 

 

 

 

32

Page 32