Butane

30

65

127

-

 

 

 

(G30)

 

 

 

 

 

 

 

Propane

37

65

125

-

 

 

 

(G31)

 

 

 

 

 

 

Rapid

Natural

20

115

-

286

3.00

1.05

 

(G20)

 

 

 

 

 

 

 

Butane

30

85

254

-

 

 

 

(G30)

 

 

 

 

 

 

 

Propane

37

85

250

-

 

 

 

(G31)

 

 

 

 

 

 

Wok

Natural

20

135

-

286

3.50

1.80

 

(G20)

 

 

 

 

 

 

 

Butane

30

95

218

-

 

 

 

(G30)

 

 

 

 

 

 

 

Propane

37

95

214

-

 

 

 

(G31)

 

 

 

 

 

 

oReassemble all the burners carefully; in particular you should make sure that the flame spreader is correctly placed on the burner.

IMPORTANT: After changing the injectors YOU MUST follow the minimum flow adjustment section on the next page.

Minimum flow adjustment for hob gas taps.

All work must be carried out by a GASSAFE registered engineer.

o Light the burner and set the knob at the minimum position.

o Remove the knob from the tap and place a small bladed screwdriver in the centre of the tap shaft.

oUnscrew the adjusting screw, in order to increase the gas flow or tighten the adjusting screw to decrease the gas flow.

oThe correct adjustment is obtained when the flame has a length of about 3 – 4 mm.

33

Page 33
Image 33
Baumatic BC190.2TCSS manual Minimum flow adjustment for hob gas taps