Baxi Potterton BBU 15 HE manual Sealed Systems

Models: BBU 15 HE

1 44
Download 44 pages 8.24 Kb
Page 14
Image 14

 

 

Temporary

 

 

Hose

Mains Water

Hose

Stop

Supply

Union

Valve

(Service Pipe)

 

 

 

 

 

Double

 

 

Check

 

 

Valve

 

 

Heating

 

 

System

4.0System Details

4.7Sealed Systems (cont)

4.Expansion Vessel. A diaphragm type expansion vessel to BS 4814:1 shall be fitted close to the inlet side of the pump. The connecting pipework should not be less than 15mm.

Pipework connecting the expansion vessel should not incorporate valves of any sort.

Methods of supporting the vessel are supplied by the vessel manufacturer.

The nitrogen or air charge pressure of the expansion vessel shall not be less than the hydrostatic head, (height of the top point of the system above the expansion vessel). To size the expansion vessel it is first necessary to calculate the volume of water in the system in litres. The following volumes may be used as a conservative guide to calculating the system volume.

Filling a Sealed Water System (Method 1)

Mains Topping Up Method

NOTE: This method of filling a sealed system may only be used if acceptable to Local Water Undertaking

Mains Water

Supply

Cistern

Filling a Sealed Water System (Method 2)

Cistern Filling Method

NOTE: Cistern to be supplied through a temporary connection from a service pipe or cold water distributing pipe

Fig. 7

Pressure Pump Reducing Valve (if required)

Stop

Valve

Heating

System

Fig. 8

Boiler Heat Exchanger:

1.55 litres

Small Bore Pipework:

1 litre per kW of system output

Micro Bore Pipework:

7 litre

Steel Panel Radiators:

8 litre per kW of system output

Low Water Capacity Radiators:

1 litre per kW of system output

Hot Water Cylinder:

1 litre per kW of system output

If the system is extended, the expansion vessel volume may have to be increased unless provision has been made for extension. Where a vessel of the calculated size is not available, the next available larger size should be used.

The boiler flow temperature is controlled at approx. 75°C.

The vessel size can now be determined from the information in table 1 where V = System volume in litres.

5.Cylinder. The hot water cylinder must be an indirect coiler type.

6.Method of Make Up. Provision shall be made for replacing water loss from the system either:-

a)From a make up vessel or tank mounted in a position higher than the top point of the system and connected through a non-return valve to the system on the return side of the hot water cylinder or the return side of all heat emitters.

or

b)Where access to a make up vessel would be difficult by using the mains top up method or a remote automatic pressurisation and make up unit.

7.Mains Connection. There shall be no connection to the mains water supply or to the water storage tank which supplies domestic hot water even through a non-return valve, without the approval of the Local Water Authority.

8.Filling Point. A filling point connection on the central heating return pipework must be provided to facilitate initial filling and pressurising and also any subsequent water loss replacement/refilling.

The sealed primary circuits may be filled or replenished by means of a temporary connection between the circuit and a supply pipe, provided a ‘Listed’ double check valve or some other no less effective backflow prevention device is permanently connected at the inlet to the circuit and the temporary connection is removed after use.

Vessel Charge Pressure (bar)

0.5

1.5

Initial System Pressure (bar)

1.0

1.0

Expansion Vessel Volume (litres)

V x 0.11

V x 0.087

 

 

 

Table 1

The filling method adopted must be in accordance with all relevant water supply regulations and use approved equipment.

Your attention is drawn to: for GB: Guidance G24.2 and recommendation R24.2 of the Water Regulations Guide. for IE: the current edition of IS 813 “Domestic Gas Installations”.

14© Baxi Heating UK Ltd 2009

Page 14
Image 14
Baxi Potterton BBU 15 HE manual Sealed Systems

BBU 15 HE specifications

The Baxi Potterton BBU 15 HE is a high-efficiency boiler designed to offer exceptional performance for both heating and hot water needs in residential settings. Known for its robust build quality and user-friendly features, this model is particularly favored for its versatility and reliability in various home environments.

One of the standout features of the Baxi Potterton BBU 15 HE is its compact size, making it suitable for installation in smaller spaces. Despite its small footprint, it delivers impressive outputs, making it ideal for homes with moderate heating demands. The boiler’s high efficiency rating ensures reduced energy consumption, leading to lower utility bills and a smaller carbon footprint.

Equipped with a powerful heat exchanger, the BBU 15 HE maximizes heat transfer, ensuring that households receive optimum warmth and hot water. With an output capacity of 15 kW, it can effectively heat a variety of living spaces while providing hot water on demand, making it a practical choice for families.

The boiler incorporates a number of advanced technologies that enhance its performance. One such feature is the built-in frost protection, which helps prevent the system from freezing during colder months. Additionally, the BBU 15 HE is designed for easy maintenance, featuring a simple access point for servicing, which can prolong the boiler’s lifespan and improve overall efficiency.

Safety is a top priority in any boiler installation, and the Baxi Potterton BBU 15 HE includes multiple safety features such as a pre-set temperature limit that prevents overheating and a pressure relief valve to manage excessive pressure within the system. These elements contribute to a safer home environment, providing peace of mind for homeowners.

Furthermore, the boiler is designed to operate quietly, minimizing disruptions in the home when heating systems are active. This is an important factor for many households where comfort is a priority.

In summary, the Baxi Potterton BBU 15 HE is a compact, efficient, and reliable boiler that provides an optimal solution for home heating and hot water needs. Its advanced features, safety systems, and user-friendly design make it a popular choice among homeowners, ensuring a cozy and comfortable living environment. Whether for a new installation or a replacement unit, this boiler stands out as a highly effective option in the market.