Baxi Potterton Gold FSB 30 HE 240V at a ?, 240V at B ?, 240V at C ?, 240V at D ?, PCB fuse OK ?

Models: Gold FSB 30 HE

1 60
Download 60 pages 23.16 Kb
Page 51
Image 51

ELECTRICAL SUPPLY

NO

240V at A ?

YES

Lights

Off Off Off

No Permanent Live to boiler. Check Mains Fuse and

System Wiring.

17.0Fault Finding

A

B

NO

240V at B ?

YES

NO

240V at C ?

YES

NO

240V at D ?

YES

NO

PCB fuse OK ?

YES

Replace PCB.

No Switched Live to boiler. Check System Controls and System Wiring.

Check P/L wiring from terminal block to PCB.

Check S/L wiring from terminal block to PCB.

Check for short circuit on condensate pump, fan & gas valve. Replace if shorted & replace fuse.

S/L N P/L

C

Fuse

D

 

© Baxi Heating UK Ltd 2011

51

Page 51
Image 51
Baxi Potterton Gold FSB 30 HE manual 240V at a ?, 240V at B ?, 240V at C ?, 240V at D ?, PCB fuse OK ?, N P/L Fuse