Baxi Potterton Gold FSB 30 HE manual Pipework, Low Head Installation, Air Vents

Models: Gold FSB 30 HE

1 60
Download 60 pages 23.16 Kb
Page 12
Image 12

Boiler Air

Vent

 

Copper

Copper

0.5m

0.5m

Flow

Boiler

Return

 

Copper

 

1m

 

Fig. 9

500mm

22mm

45°

Open Vent

 

6.0 System Details

6.3Pipework

1.The sizes of flow and return pipes from the boiler should be determined by normal methods, according to the requirements of the system.

2.The connection tails for the boiler are 28mm diameter. The 28mm section of the tails can be cut back to 22mm if required.

3.The flow & return tails are push - fit ‘O’ ring

Boiler Air

Vent

Boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

1000mm

 

 

15mm

 

 

 

 

 

Min

 

 

 

400mm

 

 

 

Cold

 

 

 

 

 

 

 

Feed

 

Min Head

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150mm

Max

Pump

Flow

Return

and clip connections within the boiler case.

4. A 20 °C drop in temperature across the system is

recommended for condensing boilers. Existing radiators

may be oversized and so allow this, but where radiator

sizing is marginal it may be advisable to retain a system

temperature drop of 11°C.

5. In systems using non-metallic pipework it is necessary

to use copper pipe for the boiler Flow and Return. The

copper must extend at least 1 metre from the boiler and

include any branches (Fig. 9).

Fig. 10

Typical Low Head Installation

6. This boiler does not require a bypass.

Boiler Air

Vent

Boiler

500mm

22mm

 

Open Vent

 

 

 

 

 

45°

 

 

 

15mm

400mm

 

1000mm

Cold

 

Min Head

 

Min

Feed

 

 

 

150mm

 

 

Max

 

 

 

 

 

Pump

 

 

Return

Flow

 

 

 

6.4Low Head Installation

1.Using a close couple arrangement the minimum head is as shown in the diagrams (Figs. 10 & 11) subject to the following conditions:

a)The pump being adjusted to give a 20°C drop across the boiler.

b)The pump must be fitted on the flow.

c)The pump must be fitted in accordance with the pump manufacturer's instructions.

d)The open vent pipe must be taken up from a tee in a horizontal section of the flow pipe.

2. For heads below 400mm then an alternative utilising a

combined vent and feed pipe may be connected (Fig. 12).

Fig. 11

If Conditions Require,

This System Possible

 

 

200mm

22mm

Boiler Air

Feed & Vent

Min

Pipe

Vent

 

 

 

 

 

Air

 

 

Separator

Boiler

 

Pump

 

 

Flow

 

 

Return

Fig. 12

Alternative Low Head Installation

This must be a minimum of 22mm diameter. It is

recommended that an air separator is fitted when using a

combined feed and vent pipe.

6.5

Air Vents

For correct operation of the flow switch the boiler and system MUST be completely vented.

1.A manual air vent is fitted on the flow pipe, to enable complete venting of the boiler. The pipe access panel must be removed to do this.

2.Additional vents should be fitted at suitable points on the system as required.

12© Baxi Heating UK Ltd 2011

Page 12
Image 12
Baxi Potterton Gold FSB 30 HE manual Pipework, Low Head Installation, Air Vents

Gold FSB 30 HE specifications

The Baxi Potterton Gold FSB 30 HE is a high-efficiency system boiler designed to meet the demands of modern homes while providing exceptional performance and reliability. As part of the Baxi Potterton Gold range, this model combines advanced engineering with user-friendly features, making it a top choice for homeowners and installers alike.

One of the primary features of the Baxi Potterton Gold FSB 30 HE is its impressive efficiency rating. With an ErP rating of A for heat and a seasonal efficiency of up to 90%, this boiler not only reduces energy consumption but also helps in lowering utility bills. The high-efficiency design ensures that more of the fuel consumed is converted into usable heat, making it an environmentally friendly option.

The boiler utilizes a lightweight design, weighing in at just 30 kg, which makes it easy to transport and install. Its compact size allows for flexibility in siting, meaning it can fit comfortably in kitchen cupboards or utility rooms without taking up excessive space. The small footprint caters to property owners looking to save on installation areas while still having a powerful heating system.

In terms of technology, the Baxi Potterton Gold FSB 30 HE features an integral thermostat and a user-friendly LCD display for easy boiler operation and maintenance. This advanced control system provides homeowners with accurate temperature readings and the ability to adjust settings with ease. The built-in diagnostics feature simplifies fault-finding and allows for quick resolutions, minimizing downtime.

The boiler is also equipped with weather compensation technology, which adjusts the heating output based on the external temperature. This ensures optimal performance year-round, maintaining a comfortable environment inside the home and optimizing energy use.

Safety features are paramount in the design of the Baxi Potterton Gold FSB 30 HE. It includes a range of built-in safeguards, such as a frost protection mode and an overheat thermostat, giving users peace of mind. Moreover, it is compatible with various heating controls and can be linked to smart home systems, offering further convenience and energy-saving options.

Overall, the Baxi Potterton Gold FSB 30 HE stands out for its efficiency, compact design, and advanced technology, making it a reliable solution for domestic heating needs. With a solid reputation for quality and performance, the Gold FSB 30 HE continues to be a favored choice for those looking to invest in an effective system boiler.