4.0Technical Data

4.1Gold Combi 24, 28 & 33 HE A

Appliance Type

 

 

 

C13

C33

C53

 

 

Appliance Category

CAT I 2H

 

 

 

Heat Input CH (Net)

Max

Min

 

 

24 model

 

kW

20.5

7

 

 

28 model

 

kW

24.7

9

 

 

33 model

 

kW

28.9

9.7

 

 

 

 

 

 

 

 

 

 

Heat Input CH (Gross)

Max

Min

 

 

24 model

kW

22.7

7.8

 

 

28 model

kW

27.4

10

 

 

33 model

kW

32.1

10.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Output CH (Non-Condensing)

 

 

 

 

 

 

 

 

 

 

 

 

Max

Min

 

 

24 model

 

kW

20

6.8

 

 

28 model

 

kW

24

8.7

 

 

33 model

 

kW

28

9.4

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Output CH (Condensing)

 

 

 

 

 

 

 

 

 

 

 

 

Max

Min

 

 

24 model

 

kW

21

7.4

 

 

28 model

 

kW

25.9

9.5

 

 

33 model

 

kW

30.3

10.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input DHW (Net)

Max

 

 

 

 

24 model

 

kW

24.7

 

 

 

 

28 model

 

kW

28.9

 

 

 

 

33 model

 

kW

34

 

 

 

 

 

 

 

 

 

 

Heat Input DHW (Gross)

Max

 

 

 

24 model

 

kW

27.4

 

 

 

28 model

 

kW

32.1

 

 

 

33 model

 

kW

37.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Output DHW

Max

 

 

 

 

24 model

 

kW

24

 

 

 

 

28 model

 

kW

28

 

 

 

 

33 model

 

kW

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Gas Rate (Natural Gas - G20)

 

 

 

 

 

 

 

 

 

(After 10 mins)

 

 

 

 

 

24 model

 

m3/h

2.61

 

 

 

 

 

28 model

 

m3/h

3.1

 

 

 

 

 

33 model

 

m3/h

3.6

 

 

 

Inlet Pressure (Natural Gas - G20)

mbar

20

 

 

 

 

 

 

 

 

 

 

Injector (Natural Gas - G20)

 

 

 

7.5mm (24&28 model)

12mm(33 model)

 

 

 

 

 

 

Electrical Supply

 

230V~ 50Hz

(Appliance must be connected to an

earthed supply)

 

 

 

 

 

 

 

 

 

 

 

 

Power Consumption

 

 

 

 

155W (24 & 28 model)

160W (33 model)

 

 

 

 

 

 

 

 

Electrical Protection

 

 

 

 

 

 

 

 

IPX0D

 

 

 

 

 

 

 

External Fuse Rating

 

3A

 

 

 

 

 

 

 

 

Internal Fuse Rating

 

F2L

 

 

 

 

 

 

 

 

Condensate Drain

To accept 21.5mm (3/4 in) plastic waste pipe

Flue Terminal

Diameter

100mm

Dimensions

Projection

125mm

 

 

 

 

 

 

Connections

 

 

 

copper tails

Gas Supply

 

 

-

22mm

Central Heating Flow

 

 

-

22mm

Central Heating Return

-

22mm

Cold Water Mains Inlet

-

15mm

DHW Flow

 

 

-

15mm

Pressure Relief Discharge

-

15mm

 

 

 

 

 

 

 

 

 

Outercase Dimensions

 

 

 

 

Casing Height

 

 

 

- 780mm

Overall Height Inc Flue Elbow

- 965mm

Casing Width

 

 

 

- 450mm

Casing Depth

 

 

 

- 345mm

 

 

 

 

 

 

 

 

 

 

Clearances

 

 

 

 

 

 

Above Casing

200 mm Min

 

 

Below Casing

200 mm Min

 

 

Front

450 mm Min (For Servicing)

Front

5 mm Min (In Operation)

L.H. Side

5 mm Min

 

 

 

R.H. Side

5 mm Min (In Operation)

 

 

 

 

 

 

 

 

 

Weights (kg)

 

 

 

 

 

 

 

 

 

 

 

 

(24)

(28)

(33)

 

Packaged Boiler Carton

48.6

49.2

51

 

Installation Lift Weight

43.6

44.2

46

 

NOx Class

 

5

 

 

Central Heating Primary Circuit

 

Pressures

 

 

 

 

 

 

 

 

 

 

bar

Safety Discharge

 

 

 

3

Max Operating

 

 

 

2.5

Min Operating

 

 

 

0.5

Recommended Operating Range

1-2

 

 

 

 

 

 

 

DHW Circuit

 

bar

 

Pressures

 

 

 

 

Max Operating

 

8

 

 

Min Operating

 

0.15

 

 

 

 

 

 

 

 

Flow Rates

(24)

(28)

(33)

 

 

 

l/min

l/min

l/min

DHW Flow Rate

 

 

 

 

@ 30o CRise

11.43

13.3

15.7

DHW Flow Rate

 

 

 

 

@ 35o CRise

9.8

11.5

13.5

Min Working

 

 

 

 

DHW Flow Rate

2

2

 

2

 

 

 

 

 

 

Pump

 

 

 

 

Available Head

See graph below

 

 

 

 

Expansion Vessel

- (For Central Heating

only. Integral with appliance)

 

 

 

 

 

 

 

bar

 

Min Pre-charge Pressure

0.5

 

 

 

 

 

(24,28)

(33)

Max Capacity of

 

litre

litre

CH System

 

125

155

Primary Water Content

 

 

 

of Boiler (unpressurised)

2.5

2.8

Temperatures

C.H. Flow Temp (adjustable)

25°C to 80°C max (± 5°C)

D.H.W. Flow Temp (adjustable)

35°C to 60°C max (± 5°C) dependent upon flow rate

SEDBUK Declaration

The efficiency is 91.1% (all models)

This value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated has been certified by 0087.

Pump - Available Head

 

5.5

 

5

 

4.5

 

4

 

3.5

 

3

(wg)

2.5

 

Metre

2

1.5

 

 

1

0.5

0

0

200

400

600

800

1000

1200

10© Baxi Heating UK Ltd 2008

Flow Rate (l/h)

Page 10
Image 10
Baxi Potterton Gold HE A Range manual Technical Data, Gold Combi 24, 28 & 33 HE a