18.0 Fault Finding

I

1.

2.

Check the gas supply pressure: For Natural Gas greater than 10 - 11 mbar

Check and correct if necessary

1.The mechanical set of the gas valve (CO2 values - see instruction)

2.Flame sensing electrode and lead connections

3.Flame sensing electrode position

Flame current should be more than 0.5 μA

YES

Replace PCB

NO

Replace flame sensing electrode

J

1.

Overheat thermostat operated or

NO

 

 

Allow to cool. Continuity

YES

 

 

 

 

Replace safety thermostat

 

faulty, i.e. continuity across

 

 

 

across thermostat terminals

 

 

 

 

 

 

thermostat terminals

 

 

 

more than 1.5 ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

Is there 230V at:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

Motor 3-way valve

 

 

 

Replace motor 3-way valve

 

 

 

NO

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCB - X3 connector terminals

 

Replace PCB

 

 

 

 

 

 

 

 

5

& 6 central heating mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

& 7 domestic hot water mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change pump supply cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

M

1.

1.

Fan connections correct at fan.

PCB - X401 connector terminals 5,6,7 & 8

Temperature sensors faulty.

Cold resistance approximately

YES

NO

Replace fan

10kΩ @ 25° C (CH sensor) 20kΩ @ 25° C (Flue sensor)

(resistance reduces with increase in temp.)

Replace sensor

2.

If pump is running the heat exchanger could be obstructed

YES

Replace heat exchanger

© Baxi Heating UK Ltd 2008