Image 21

Type "Y" to change the Attention Character. The V93A will respond with:

Enter Attention Character :

Type the desired Attention Character. For example, if you type "%", the V93A will respond with

Attention

Character

is

%

Change It

? (Y/N) :

 

 

Type "N" if no additional change is desired. The V93A will store the new Attention Character into non-volatile memory and return to the main configuration menu.

.6 DISCONNECT TIME GUARD

By responding with "6" (Disconnect Time Guard), you can determine if you want a one second delay. The V93A will respond with:

Disconnect

Time Guard is

Enabled

Change It?

(Y/N):N

 

Type "Y", to toggle the existing state of Disconnect Time Guard or "N" for no change. The V93A will store the selected state of the Disconnect Time Guard into non-volatile memory and return to the main configuration menu.

.7 LOGIN PASSWORD

By responding with "7" (Login Setup), you can change the Login Password. The V93A will respond with:

Login Password Is

BTA

Change It: (Y/N):

 

Type “Y” to enter the new password up to 8 ASCII characters followed by <ENTER>. For example, if you what to change the Login Password to LOGIN, type "LOGIN" at the prompt. The V93A will respond with: