Beckett AFII manual Section Perform Regular Maintenance, HLX Firing Rate, HLX Air Dial Setting

Models: AFII

1 20
Download 20 pages 63.93 Kb
Page 18
Image 18
HLX Firing Rate

Section: Perform Regular Maintenance

HLX Firing Rate

Stop

AFII 85

AFII 100

AFII 150

Screw

 

 

 

0

0.40-0.65

0.5-0.65

0.75-1.00

 

 

 

 

1

-

0.6-0.75

0.85-1.10

 

 

 

 

2

-

0.65-0.80

0.95-1.15

 

 

 

 

3

0.60-0.75

0.65-0.90

0.95-1.20

 

 

 

 

4

-

0.75-0.95

1.10-1.25

 

 

 

 

5

0.70-0.85

0.85-1.00

1.15-1.35

 

 

 

 

6

-

0.95-1.10

1.15-1.40

 

 

 

 

7

-

-

1.25-1.50

 

 

 

 

8

-

-

1.30-1.50

 

 

 

 

HLX Air Dial Setting

Firing Rate

AFII 85

AFII 100

AFII 150

@ 140 psig

 

 

 

0.40-0.65

3

-

-

 

 

 

 

0.60-0.75

4

3

-

 

 

 

 

0.70-0.85

5

4

-

 

 

 

 

0.75-1.00

-

5

2

 

 

 

 

0.95-1.20

-

-

3

 

 

 

 

1.15-1.35

-

-

4

 

 

 

 

1.25-1.50

-

-

5

 

 

 

 

FBX Firing Rate

Head

AFII 85

 

AFII 100

 

AFII 150

 

 

 

 

 

 

 

 

FB0

0.40-0.65

 

0.55-0.75

0.75-1.00

 

 

 

 

 

 

 

 

FB3

0.55-0.85

 

0.55-1.10

0.85-1.20

 

 

 

 

 

 

 

 

FB4

 

-

 

0.75-1.10

1.10-1.25

 

 

 

 

 

 

 

 

FB6

 

-

 

0.85-1.15

 

1.15-1.35

 

 

 

 

 

 

 

 

FBX Air Dial Setting

 

 

 

 

 

 

 

 

 

Firing Rate @

AFII 85

 

AFII 100

AFII 150

140 psig

 

 

 

 

 

 

0.40-0.65

3

 

 

-

 

-

 

 

 

 

 

 

 

0.60-0.75

4

 

 

3

 

-

 

 

 

 

 

 

 

0.70-0.85

5

 

 

4

 

-

 

 

 

 

 

 

 

0.75-1.00

-

 

 

5

 

2

 

 

 

 

 

 

 

0.95-1.20

-

 

 

-

 

3

 

 

 

 

 

 

 

1.15-1.35

-

 

 

-

 

4

 

 

 

 

 

 

 

1.25-1.50

-

 

 

-

 

5

 

 

 

 

 

 

 

 

18

Page 18
Image 18
Beckett AFII manual Section Perform Regular Maintenance, HLX Firing Rate, HLX Air Dial Setting, FBX Firing Rate