PB9200-e.book Page 37 Thursday, May 27, 2004 2:15 PM

Replacing The Lamp

If the indicators or a message prompts you to replace the lamp, replace the lamp as soon as possible.

1.Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 45 minutes.

2.Contact your dealer to prepare a new lamp. Tell the dealer your lamp type number. If the projector is mounted on the ceiling, or if the lamp has broken, also ask the dealer to replace the lamp.

In the case of replacement by yourself,

3.After making sure that the projector has cooled adequately, slide the knob of a lamp cover lock as shown in the Figure. Then, one side of the lamp cover is raised. Pull up the lamp cover and remove it, as shown in the Figure.

4.Unscrew the 3 screws, and slowly pull out the lamp by the handle. Be careful not to touch the inside of the lamp case.

5.Insert the new lamp, and tighten the 3 screws firmly to lock it in place.

6.Interlocking the 2 tabs of the lamp cover to the projector, put the lamp cover on the projector. Then push the point of the lamp cover to fix it, as shown in the Fig- ure. Make sure that the lamp cover does’t come up.

7.Turn on the projector, and reset the lamp timer.

(1)While the projector running, press the MENU button to open the menu.

Lamp cover knob

Lamp cover

Screws

PC

P

CO LAM

Tabs

(2)Choose the “OPTION” on the menu using the 5 / 6button, then press the button or ENTER button.

(3)Choose the “LAMP TIME” using the 5 / 6 button, then press and hold the RESET button for 3 seconds.

(4)Choose the “RESET” using the 5 button.

memo When the lamp has been replaced after the message of "THE POWER WILL TURN OFF AFTER 0hr." is displayed, complete this operation within 10 minutes of switching power on.

memo Incorrectly resetting of the lamp timer (resetting without replacement, or neglect of resetting after replacement) will result in incorrect message functions.

Lamp 37