Related Messages (continued)
|
| Message | Description | ||
|
|
|
|
|
|
|
| CLEAN THE AIR FILTER | The time the filter timer has counted has reached | ||
|
| POWER OFF FIRST, | 100 hours. | ||
|
| Please clear or change the air filter by referring to | |||
|
| THEN CLEAN THE AIR | |||
|
| the section “Air Filter”. After caring for the air filter, | |||
|
| FILTER. | please be sure to reset the filter timer. | ||
|
| AFTER CLEANING THE AIR |
| ||
|
| FILTER, |
| ||
|
| RESET THE FILTER TIMER. |
| ||
|
|
|
|
|
|
|
|
|
|
| The internal portion temperature is rising. |
|
|
|
|
| Please turn the power OFF, and allow the unit to |
|
|
|
|
| cool down at least 20 minutes. After the projector |
|
|
|
|
| has sufficiently cooled down, please make confir- |
|
| CHECK THE AIR FLOW | mation of the following items, and then turn the | ||
|
|
|
|
| power on again. |
|
|
|
|
| • Is there blockage of the air passage aperture? |
|
|
|
|
| • Is the air filter dirty? |
|
|
|
|
| • Does the peripheral temperature exceed 35°C? |
|
|
|
|
|
|
|
|
|
|
| There is no input signal. |
|
| NO INPUT IS DETECTED |
| ||
|
|
| Please confirm the signal input connection, and the | ||
|
| ON *** |
| ||
|
|
| status of the signal source. | ||
|
|
|
|
|
|
|
|
|
|
| The horizontal or vertical wavelength of the |
|
|
|
|
| inputted signal is outside of the response |
|
| SYNC IS OUT OF RANGE |
|
| |
|
|
| parameters of this unit. | ||
|
| ON *** fH *****kHz fV *****Hz |
|
| |
|
|
| Please confirm the specs for this unit or the signal | ||
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| source specs. |
|
|
|
|
|
|
Troubleshooting 41