BenQ W9000, W10000 manual Replacing the lamp, Lamp cover located on the left side

Models: W9000 W10000

1 37
Download 37 pages 39.48 Kb
Page 34
Image 34

English

Replacing the lamp

The lamp may be very hot. Allow the projector to cool for at least 45 minutes before replacing the lamp.

This lamp contains mercury. Consult your local hazardous waste regulations to dispose of this lamp in a proper manner.

1. Turn the power off and disconnect the

2. Slightly lift the projector up. Loosen the screws on

projector from the wall socket. Turn off all

the lamp cover (located on the left side).

connected equipment and disconnect all other

 

cables.

 

3.Remove the lamp cover.

5.Slowly pull the lamp out of the projector.

4.Loosen the screws that hold the lamp to the projector. If the screws are not loosened completely, they could injure your fingers. It is strongly recommended that you use a magnetic- head screwdriver to retain the screw should it come loose.

6.Insert the replacement lamp. Make sure it is pushed fully and firmly in place.

7.Tighten the screws securing the lamp box.

Pulling it too quickly may cause the lamp to

break and scatter broken glass in the projector. To reduce the risk of injuries to fingers and damage to internal components, use caution when removing lamp glass that has shattered.

Do not place the lamp in locations where water

might splash on it, children can reach it, near or above heat sources, or near flammable materials.

Do not insert your hand into the projector

when the lamp is removed. If you touch the optical components inside, it could cause blurred images.

Please be careful to not over-tighten the screws.

Loose screws may cause a bad connection, which could result in malfunction.

8.Re-install the lamp cover.

9.Tighten the screws on the lamp cover.

10. Turn the power on and go into Setup > Lamp > Reset Lamp Timer menu to reset the lamp time.

Do not reset the lamp timer if the lamp has not been replaced as this could cause damage.

34 Additional information

Page 34
Image 34
BenQ W9000, W10000 manual Replacing the lamp, Lamp cover located on the left side, Tighten the screws securing the lamp box