BREW TIMER ADJUSTMENT

SERVICING INSTRUCTIONS (continued)

Adjustments to be performed by qualified technician only.

NOTE:

Brewer is pre-adjusted to deliver 1/2, 1 and/or 1-1/2 gallons of coffee at a water pressure of 50 p.s.i. Use this procedure to adjust the delivered volume to suit local conditions.

Adjust only in small increments to avoid large volume variations. Recommend knob be turned no more than one mark on the dial plate at a time.

Moving the dial one mark will change delivered volume by approximately 6 oz.

BREW TIMER ADJUSTMENT

PRECAUTIONS: None

FREQUENCY:

As required to adjust delivered volume

TOOLS:

Small flathead screwdriver

 

Satellite or other container to calibrate volume

 

 

 

 

1.Press TANK HEATER switch to OFF.

2.Remove TIMER ACCESS COVER on front panel. Press VOLUME SELECTOR to 1 GAL position.

3.Install an empty satellite and empty brew chamber.

4.Press START BREW switch. Brew should deliver 1 gallon

(128 fl. oz.). If adjustment is necessary, turn TIMER knob:

Turn CLOCKWISE to increase time;

Turn COUNTER-CLOCKWISEto decrease time.

Test after each adjustment. Be sure to empty satellite before each test.

5.Turn TANK HEATER switch ON.

6.Allow the brewer to come up to brewing temperature, then perform a test brew. Check delivered volume. Readjust as necessary.

7.Reinstall TIMER ACCESS COVER.

When desired volume is achieved, procedure is complete.