SERVICING INSTRUCTIONS (continued)
Adjustments to be performed by qualified technician only.
NOTE:
Brewer is
Adjust only in small increments to avoid large volume variations. Recommend knob be turned no more than one mark on the dial plate at a time.
Moving the dial one mark will change delivered volume by approximately 6 oz.
BREW TIMER ADJUSTMENT
PRECAUTIONS: None
FREQUENCY: | As required to adjust delivered volume |
TOOLS: | Small flathead screwdriver |
| Satellite or other container to calibrate volume |
|
|
|
|
1.Press TANK HEATER switch to OFF.
2.Remove TIMER ACCESS COVER on front panel. Press VOLUME SELECTOR to 1 GAL position.
3.Install an empty satellite and empty brew chamber.
4.Press START BREW switch. Brew should deliver 1 gallon
(128 fl. oz.). If adjustment is necessary, turn TIMER knob:
Turn CLOCKWISE to increase time;
Turn
Test after each adjustment. Be sure to empty satellite before each test.
5.Turn TANK HEATER switch ON.
6.Allow the brewer to come up to brewing temperature, then perform a test brew. Check delivered volume. Readjust as necessary.
7.Reinstall TIMER ACCESS COVER.
When desired volume is achieved, procedure is complete.
663 76061 Owners Manual for 9102A Single Satellite Brewer
14