Bloomfield BYPASS ADJUSTMENT 9104A ONLY, SERVICING INSTRUCTIONS continued, Bypass Gauge Set

Models: 9104A 9102A

1 26
Download 26 pages 18.25 Kb
Page 17
Image 17
BYPASS ADJUSTMENT (9104A ONLY)

SERVICING INSTRUCTIONS (continued)

Manual for 9102A Single Satellite Brewer

BYPASS ADJUSTMENT (9104A ONLY)

PRECAUTIONS:

Disconnect brewer from electric power.

 

Allow brewer to cool.

FREQUENCY:

As required to adjust for change in delivered

 

volume, or to taste.

TOOLS:

Phillips head screwdriver

 

Stubby flathead screwdriver

 

Provided wire gauge set

 

 

1.Press TANK HEATER switch to OFF. Disconnect brewer from electrical power.

2.Remove SATELLITE, BREW CHAMBER, TOP PANEL and

BASIN.

3.Turn bypass adjustment screw several turns counter- clockwise. Insert and hold appropriate gauge fully into bypass valve from the outside of the brewer.

4.Turn bypass adjustment screw clockwise until the resistance of the adjuster contacting the gauge is felt.

5.Release the gauge set. Turn bypass adjustment screw counterclockwise slowly until gauge set fall out of the valve.

6.Reassemble brewer and perform a 1 gallon brew and sample for taste. Adjust from this point to achieve desired taste:

a.Repeat steps 1 and 2.

b.Turn bypass adjustment screw counterclockwise to decrease coffee strength (increase dilution); or , clockwise to increase coffee strength (decrease dilution).

7.Perform BREW TIMER ADJUSTMENT to insure delivery of 128 oz. in 1 gallon mode.

Procedure is complete

CAUTION:

SHOCK HAZARD

Disconnect brewer from electric power before opening the top panel.

The brewer is shipped from the factory pre-set for 25% bypass. This adjustment must never be made unless the brewer is installed on a soft water line, or a change in coffee strength is required.

Bypass Gauge Set

663 76061 Owners

Bypass Adjustment

15

Page 17
Image 17
Bloomfield 9102A BYPASS ADJUSTMENT 9104A ONLY, SERVICING INSTRUCTIONS continued, Bypass Gauge Set, Bypass Adjustment