SERVICING INSTRUCTIONS (continued)
Manual for 9102A Single Satellite Brewer
BYPASS ADJUSTMENT (9104A ONLY)
PRECAUTIONS: | Disconnect brewer from electric power. |
| Allow brewer to cool. |
FREQUENCY: | As required to adjust for change in delivered |
| volume, or to taste. |
TOOLS: | Phillips head screwdriver |
| Stubby flathead screwdriver |
| Provided wire gauge set |
|
|
1.Press TANK HEATER switch to OFF. Disconnect brewer from electrical power.
2.Remove SATELLITE, BREW CHAMBER, TOP PANEL and
BASIN.
3.Turn bypass adjustment screw several turns counter- clockwise. Insert and hold appropriate gauge fully into bypass valve from the outside of the brewer.
4.Turn bypass adjustment screw clockwise until the resistance of the adjuster contacting the gauge is felt.
5.Release the gauge set. Turn bypass adjustment screw counterclockwise slowly until gauge set fall out of the valve.
6.Reassemble brewer and perform a 1 gallon brew and sample for taste. Adjust from this point to achieve desired taste:
a.Repeat steps 1 and 2.
b.Turn bypass adjustment screw counterclockwise to decrease coffee strength (increase dilution); or , clockwise to increase coffee strength (decrease dilution).
7.Perform BREW TIMER ADJUSTMENT to insure delivery of 128 oz. in 1 gallon mode.
Procedure is complete
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric power before opening the top panel.
The brewer is shipped from the factory
Bypass Gauge Set
663 76061 Owners
Bypass Adjustment
15