SERVICING INSTRUCTIONS (continued)
IMPORTANT:
The two keypad ribbon cables connectors are not polarized and can easily be installed in the wrong position. Be sure to mark the ribbon cable connectors for orientation.
REPLACE CONTROLLER
Disconnect brewer from electric power. Remove top panel
Note location of wire connections. Be sure to mark the two keypad ribbon cables as to orientation. Disconnect wiring from controller.
Remove four nuts holding controller to cabinet.
Fig. 11 Controller Wiring Configuration
Reassemble in reverse order. Be sure motor speed dip switches are set with RED 5 ON, all others OFF.
18