OPERATION (continued)

OPERATION (continued)

Fig. 5 Program Brew Select Keys

Table I.

FOUR BREW OPTIONS

B.PROGRAM BREW VOLUMES

Each BREW SELECT KEY is individually programmable.

Keys may be programmed for pulse brewing to optimize contact times and extraction rates,.

Up to 10 pulses may be programmed. Each pulse delay is fixed at 4 seconds.

Dilution for each BREW SELECT KEY is individually programmable (usually used for brewing tea).

1.Load a fresh pod in the pod holder and lock the pod in place. Place an empty cup on the cup grid. See page 9.

2.Press and hold both BREW SELECT KEYS for 5 seconds until a beep sounds.

3.Program BREW 1 SELECT key

IMPORTANT: Allow for an additional 2 oz to be pushed through during the drying cycle at the end of the brew.

a.Press and release the key to start water flow.

b.Press and release the key to stop water flow when desired volume is reached. Press and hold the key for 3 seconds (until a beep sounds) to enter the setting into memory.

- OR -

For PULSE BREW:

a.Press and release the key to start the water flow.

b.Press and release the key again to stop the flow after the time desired for the first pulse.

c.Press the key again to resume water flow.

d.Repeat until desired total delivered volume is reached.

NOTE: Water flow can be stopped and restarted up to 10 times per brew. The delay between pulses is fixed at 4 seconds.

- AND -

For DILUTION:

a.Press and release the BREW 2 SELECT KEY to start hot water flow at any time during the programming sequence.

b.Press and release the key again to stop the flow when the desired amount of hot water is reached.

4.Press and hold the BREW KEY for 3 seconds (until the beep sounds) enters these settings into memory.

NOTE: Pod must be refreshed before operation can resume.

5.Repeat steps 1 through 4 for BREW 2 SELECT KEY.

NOTE: In this mode, BREW 1 SELECT KEY is used to program dilution.

6.Run a normal brew to verify settings.

NOTE: Pump is factory programmed to run for 15 seconds at the end of the brew cycle. Pulling air from the vent tube will dry the used pod.