Bloomfield 9600 Single Cup SERVICING INSTRUCTIONS continued, Wrench #86660 Clean Strainer Screen

Models: 9600 Single Cup

1 28
Download 28 pages 57.12 Kb
Page 18
Image 18
Fig. 9 Wrench #86660

SERVICING INSTRUCTIONS (continued)

Fig. 9 Wrench #86660

Fig. 10 Clean Strainer Screen

REPLACE SOLENOID

Symptom: Brewer will not flow water; or, brewer drips continuously from pod holder or brew nozzle.

NOTE: Wrench p/n 86660 is designed to allow easy removal of flare nuts from the water inlet fitting

IMPORTANT: Shut-off water to brewer and disconnect brewer from electric power before removing hoses or wiring.

Remove water supply flare fitting:

a.Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve.

b.Hold the wrench to prevent the inlet fitting from turning while installing or removing the inlet water supply flare nut.

Remove fill tubing: Disconnect wiring.

Remove two screws holding solenoid to access door. Reassemble in reverse order.

CLEAN SOLENOID SCREEN

Symptom: Automatic brewer will not flow water.

Disconnect brewer from electric power. Turn OFF and disconnect water supply from brewer inlet fitting.

Unscrew water inlet fitting from solenoid.

Using needle-nose pliers, withdraw strainer screen from solenoid. Clean screen under faucet. A stiff bristle brush may be used if necessary.

Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.)

Reassemble in reverse order.

16