![Music Source](/images/new-backgrounds/76754/7675461x1.webp)
CONFIGURATION 15:
SINGLE AMPLIFIER BACKGROUND MUSIC
Single amplifier BGM operation is a programmable feature that lets the PCM2000 use the paging amplifier to provide
INSTALLATION:
STEP 1: Connecting Telephone System Paging Output to the PCMTIM
•Refer to paging access modes described previously in Step 2 on pages 5 (paging port/contact closure), 7 (paging port/VOX), 9 (loop start trunk), 11 (ground start trunk), or 13 (station level/Centrex).
STEP 2: Connecting the BGM Source
•Connect the BGM source output to the PCMTIM module terminals labeled BGM SOURCE IN/RT.
STEP 3: PCMCPU Switch Settings
•Remove the switch lock on the PCMCPU module and place the PROGRAM/RUN switch to the PROGRAM position (down), the green LED will illuminate.
STEP 4:Testing the System
•Access the PCM2000 system (either use a single
•Dial 019 follow by the ( # ) key.You will hear a short double beep if the programming was accepted and stored in the system.
STEP 5: Prepare System for Operation
•Hang up the programming phone and then place the PROGRAM/RUN switch in the RUN position.The green LED will go out. Replace the switch lock.
Music Source
Bogen TP30D
POWER | UP BAND MSCAN M1 | M2 | M3 |
TP30D DIGITAL TUNER
DOWN MONO ME M4 M5 M6
BOGEN
PCM
TIM
S1
S2
S3 TEL
S4 INT
S5 SEL
S6
S7
0 1
POWER
TONE VOLUME
BGM SRC
VOLUME
NIGHT RING
TEL
LINE
OVER RIDE
IN
|
| BGM | ||
RT | SRC | |||
|
|
| ||
|
|
|
| |
NC |
|
|
|
|
COM | RLY ONE | |||
|
| |||
NO |
|
|
| |
NC |
|
|
|
|
|
|
|
| |
COM | RLY TWO | |||
|
| |||
NO |
|
|
|
|
GND ST |
32