Bogen PCM2000 manual

Models: PCM2000

1 38
Download 38 pages 435 b
Page 26
Image 26

CONFIGURATION 12:

DFT120 & TAMB WIRING DIAGRAM - LOOP START TRUNK, GROUND START TRUNK, OR STATION LEVEL

In this configuration, the telephone output is connected to the Bogen Telephone Access Module model TAMB; the TAMB module is connected to the Bogen Digital Feedback Terminator model DFT120; and the DFT120 is connected to the PCM2000 system. The TAMB module is acti- vated by the telephone system and, at the same time, the DFT120 is activated by the TAMB’s normally open contacts. Using digital technolo- gy, the DFT120 stores the DTMF tones and the paging audio.When the TAMB closed contacts are removed from the DFT120, the DFT120 activates the PCM2000 system also using normally open contacts, and plays the page (audio). In addition to the above equipment, you will also need a PRSASAC power supply and two RJ11 modular boxes.

INSTALLATION:

STEP 1: Assembling Modules and Connecting the Amplifier

Refer to step 1 on pages 5 and 17.

STEP 2: Connecting the Paging Amplifier

Follow the same procedure described previously on page 5 or 17, step 5.

STEP 3: Connecting an Analog Line or Ground Start Trunk from the Telephone System to the TAMB

Take the Analog Line or Ground Start trunk pair from the telephone system and wire it to the TAMB terminals T & R.

STEP 4: Connecting the TAMB Module to the DFT120

Using a 6-pin RJ11 modular jack, connect terminals labeled PT & PR from the TAMB to the modular jack terminals R (red) and G (green).

• Connect terminals labeled N.O. & COM from the TAMB to the modular jack terminals Y (yellow) and BK (black).

Connect a 6-pin RJ11 modular cable from the RJ11 jack to the AUDIO IN jacks on the DFT120. Place the switch labeled DL/LS to the DL (Dry Loop) position.

• Connect terminals labeled +24/48 & -24/48 from the TAMB to the PRSASAC power supply. Use pins 1 & 2 labeled 24V DC / 450 mA.

Connect the DFT120 power supply (supplied with the unit) to the DFT120.

STEP 5: Connecting the DFT120 to the PCMTIM Module

Attach a 6-pin RJ11 modular jack to the wall next to the PCM2000 unit.

• Connect terminals 3 & 4 from the DFT120 jack labeled AUDIO OUT, to the RJ11 modular jack terminals R (red) and G (green).

Connect terminals 2 & 5 from the DFT120 jack labeled AUDIO OUT (PLAY contact) to the RJ11 modular jack terminals Y (yellow) and BK (black).

Connect a 6-pin RJ11 modular cable between the RJ11 modular jack and the TEL LINE RJ11 input on the PCMTIM module.

STEP 6: Switch and Control Settings

• Set the switches 1, 2 & 4 to ON (to the right) and 3 & 5 to OFF (to the left) on the TAMB.

Set the switches 2, 3, & 7 to ON (to the right) and 1, 4, 5 & 6 to OFF (to the left) on the PCMTIM module for Paging Port Contact clo- sure operation.

STEP 7: Testing Your System

Connect the power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals observing polarity.

Connect the PCMPS2, PRSASAC, and the DFT120 power supplies and the amplifier to the AC power outlet 120V AC 60Hz.

Set the volume on your Bogen amplifier to a half turn.

• Adjust the DFT120 AUDIO OUT volume control to 50%. (You may need to readjust this control higher or lower later, after the test.)

Access the paging from the telephone system.The RECORD LED on the DFT120 must be lit showing that the DFT120 is already recording.

Dial 01 to record ZONE ONE DTMF tone followed by a test page. (Notice that you will not hear audio coming from the speakers at this point.)

Hang-up the handset.The PLAY LED on the DFT120 must light showing that the DFT120 is playing the page and you must be able to hear the page.

If the page is too low, adjust the control for optimal operation.

Note: Unlike the previous Digital Feedback Terminator (DFT30), the DFT120 will accept a Loop Start Trunk or Page Port directly connected to the unit.Therefore, when connecting to a Loop Start Trunk, a TAMB is not required. (See DFT120 manual for complete instructions.)

27

Page 26
Image 26
Bogen PCM2000 manual