CONFIGURATION 1:
PAGE PORT CONTACT CLOSURE -
In this configuration, the PCM unit responds to a contact closure on pins 2 & 5 of the TEL LINE jack on the PCMTIM module shorting the +5V source to its ground.When the closure is removed, the page ends. Audio is provided to the system through a separate pair of leads on pins 3 & 4 of the TEL LINE jack on the PCMTIM module. Pins 1 & 6 are not used in this configuration.
Note:The audio pair (page port) must pass DTMF in order to select a zone.
The required setup includes PCMTIM - PCMCPU - PCMZPM - PCMPS2. Modules must be assembled, from left to right, in this order.
INSTALLATION:
STEP 1:Assembling Modules PCMTIM to PCMCPU and to PCMZPM (see Illustration on page 38)
•Plug the
•Plug the
•Place the modules together and dress the connector cables away from the sheet metal so they will not get pinched.
•Push the two units together while aligning the locking tabs in the PCMTIM module to the locking slots in the PCMCPU module. Slide the two units until the faces of both units are even.
•Secure the two units together by tightening a screw into the screw clamp tab in the back of the PCMTIM.
•Follow the same steps to add the PCMZPM module.
Note: Do NOT connect the PCMPS2 (power supply) at this point.
STEP 2: Connecting Paging Port/Contact Closure from the Telephone System to the PCMTIM Module
•Take the page port audio pair from the telephone system and wire it to the RJ11
•Use a 4- or
STEP 3: Switch Settings
•Set the
•Set the
•Set the
• Set the Talk Back DIP switches on the PCMZPM module to the OFF position (to the left) for all zones.
•Set the OUTPUT switch on the PCMZPM module to the
STEP 4: Testing your System
•Connect power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw ter- minals observing polarity.
•At this point all the power LEDs should be lit on each module.
•Access the page port from the phone system and verify access tones (double beep) in handset.
•At this point, the system should be functioning properly.
•Disconnect Power Supply.
STEP 5: Connecting the Paging Amplifier
•Locate the terminals on the PCMCPU module labeled PA IN/RT and wire to the TIP and Ring (T & R) input on the Bogen paging amplifi- er (either
•Locate the terminals on the PCMCPU module labeled PA OUT/RT and wire to COMMON and either the 25 or 70V output on the paging amplifier.
STEP 6: Connecting 25/70V AC Speakers
•Locate the terminals on the PCMZPM module labeled ZONE A.These terminals have two connections marked + and
•Follow the same procedure for the terminals labeled ZONE B for ZONE TWO, and the terminals labeled ZONE C for ZONE THREE.
STEP 7: Testing your System
•Connect the power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals, observing polarity.
•Connect the Bogen amplifier to the AC power outlet (120V AC, 60Hz).
•Set the volume on your Bogen amplifier to a 1/2 turn.
•Access the paging from the telephone system and listen (on the handset) for the confirmation tone (double beep).
•Dial 01 to access ZONE ONE and listen (on the handset and also to the speakers) for a
•Follow the same steps for ZONES TWO (02) and THREE (03).
•Set the Bogen amplifier to the desired volume level.
5