Bosch Appliances 700 user manual Advanced Mode Network Network Access, 49.1 IPv4

Models: 700

1 82
Download 82 pages 123 b
Page 57
Image 57

AutoDome 700 Series IP PTZ Camera

Configuring the AutoDome 700 Series en 57

 

 

Idle State

Specify either Open or Closed idle state.

Operations Mode

Select one of the following modes for operation: Bistable, 0.5 s, 1 s, 5 s, 10 s, or 60 s.

Relay Follows

Select one of the following actions that the AutoDome performs after the relay is triggered:

Off

Connection

Video Alarm 1

Motion Alarm 1

Local Input 1

Remote Input 1

Relay Name

Type an optional name for the relay connection, up to 20 characters.

Trigger Relay

Click the Relay 1 button to test the relay connection.

4.48Advanced Mode: Network

4.49Network Access

The settings on this page are used to integrate the AutoDome 800 Series into an existing network.

Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.

1.Make the desired changes.

2.Click the Set and Reboot button. The AutoDome 800 Series is rebooted and the changed settings are activated.

CAUTION!

If you change the IP address, subnet mask or gateway address, the AutoDome 800 Series is only available under the new addresses after the reboot.

Automatic IP assignment

If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the AutoDome 800 Series. Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.

4.49.1IPv4

IP address

Enter the desired IP address for the AutoDome 800 Series in this field. The IP address must be valid for the network.

Subnet mask

Enter the appropriate subnet mask for the selected IP address here.

Bosch Security Systems, Inc.

User Manual

F.01U.273.798 3.0 2012.08

Page 57
Image 57
Bosch Appliances 700 user manual Advanced Mode Network Network Access, 49.1 IPv4