48 en Configuring the AutoDome 700 Series | AutoDome 700 Series IP PTZ Camera |
|
|
1.Click the Start button to activate the recording scheduler.
2.Click the Stop button to deactivate the recording scheduler. Running recordings are interrupted and the configuration can be changed.
Recording status
The graphic indicates the recording activity of the AutoDome 700 Series. You will see an animated graphic while recording is taking place.
4.37Recording Status
Certain details on the recording status are displayed here for information purposes. You cannot change any of these settings.
4.38Advanced Mode: Alarm
4.39Alarm Connections
You can select how the AutoDome 700 Series responds to an alarm. In the event of an alarm, the unit can automatically connect to a
Connect on alarm
Select On so that the AutoDome 700 Series automatically connects to a predefined IP address in the event of an alarm.
By setting Follows input 1 the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.
NOTICE!
In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind when assigning the profile (see Section 4.19 Encoder Profile, page 33).
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via
1.Select 10 from the Number of destination IP address list field.
2.Enter the address 0.0.0.0 in the Destination IP address field.
3.Enter your chosen password in the Destination password field.
4.Define this password as the user password for all remote stations to which a connection is to be possible.
F.01U.273.798 3.0 2012.08 | User Manual | Bosch Security Systems, Inc. |