Bosch Appliances CC880, LP880 manual Codepad ID and Buzzer Tone, Partitioning

Models: LP880 CC880

1 32
Download 32 pages 44.12 Kb
Page 14
Image 14
Codepad ID and Buzzer Tone

CC880/LP880, SC8016 Operators Guide 21.0

Codepad ID and Buzzer Tone

 

 

EN 14

21.0 Codepad ID and Buzzer Tone

If you press and hold down button [8], the tone of the codepad buzzer changes. There are 50 different tones to choose from between 1500 Hz and 5000 Hz. If multiple codepads are installed, each codepad can have a different tone.

If the system is partitioned into multiple areas, the codepad displays the area that it is assigned to before the tone of the buzzer starts to change.

Table 13: Codepad ID and Buzzer Tone Change

Zone Indicator

Area Assigned

None

Not Assigned

1

Area 1

2

Area 2

3

Area 3

4

Area 4

7

Master Partitioned Keypad

22.0 Partitioning

Your control panel can be partitioned or split into four individual areas. Each areas can be operated from one master partitioned codepad, or from separate area addressable codepads.

22.1Master Partitioned Codepad Indicators

The indicators on a master partitioned codepad are configured into four groups (such as, Zone Indicators, Area On/Off Display, Area Display, and Status Indicators). Refer to Figure 7. The following is a description of what the indicators mean.

Figure 7: Master Partitioned Codepad

22.1.1Zone Indicators

Zone indicators 1 to 8 show the status of each zone. These zones belong to the area that displays the AREA DISPLAY indicator. (For example, if an indicator is displayed, that zone is unsealed. If the indicator is not displayed, that zone is sealed.)

22.1.2Area On/Off Indicators

The group of four AREA ON/OFF indicators display the status of each area. (For example, if an indicator is displayed, that area is armed. If the indicator is not displayed, that area is disarmed.)

22.1.3Area Display Indicators

The group of four AREA DISPLAY indicators show which area the zones displayed belong to. All functions entered at the keypad only affect the area the keypad displays in the AREA DISPLAY. Press the [#] key to toggle between each area.

22.1.4Status Indicators

A group of four indicators display the following:

AUX Indicator

Displays when the control panel is using the telephone line communicating with the receiving party.

MAINS Indicator

Displays the status of the AC mains power. (For example, if the indicator is illuminated, the AC mains power supply is normal. If the indicator is flashing, the AC mains power supply is disconnected or failed.)

FAULT Indicator

Displays the status of the fault register. (For example, if the FAULT indicator is flashing, the system detected a fault that was not acknowledged. If the FAULT indicator is illuminated, the fault is acknowledged. If the FAULT indicator is not illuminated, the system has no faults.)

PARTIAL Indicator

Only displays for an area armed in STAY Mode 1. (For example, if the PARTIAL indicator displays, an area is armed in STAY Mode 1. If the PARTIAL indicator does not display, no areas are armed in STAY Mode 1.)

22.2Operation of Codepads in Partitioning

Area Addressable Codepad Operations

If you have a system that is partitioned with area addressable eight zone codepads, the operating procedure is exactly the same as described for a non- partitioned system except that all operations only relate to the area the codepad is assigned to.

Master Partitioned Codepad Operations

If you have a system that is partitioned with a master partitioned codepad installed, the operating procedure is exactly the same as described for a non- partitioned system, except that all operations only relate to the area displayed by the AREA DISPLAY indicator.

Bosch Security Systems 6/04 920036O.OG.162

Page 14
Image 14
Bosch Appliances CC880, LP880 manual Codepad ID and Buzzer Tone, Partitioning, 22.1Master Partitioned Codepad Indicators