Codepad Indicators

CC880/LP880, SC8016 Operators Guide 3.0

Codepad Indicators

 

 

EN 6

Figure 3: CP5 Eight Zone LCD Codepad

Figure 4: Sixteen Zone LCD Codepad

The codepad is the communications interface between you and your alarm system. Use the codepad to issue commands. The codepad offers both visual and audible indications that guide you through the general operation.

The codepad incorporates numerous indicators. There are zone indicators that show the condition of each zone and four other indicators for general status. The following pages outline a list of situations and the relevant indicators that are seen.

3.1Zone Indicators

1 2 3 …. The zone indicators (1 to 8) display the

status of the zones. Table 2 lists the various circumstances under which the indicators display (such as, Zone Sealed/Zone Unsealed).

Table 2: Zone Indicator

Zone Indicator

Definition

On

Zone is unsealed

Off

Zone is sealed

Flashing Fast

Zone is in alarm condition

(0.25 sec. on/

 

0.25 sec. off)

 

Flashing Slow

Zone is manually isolated or

(1 sec. on/1 sec. off)

selected to be isolated

3.2AWAY Indicator

 

The AWAY indicator shows the system

 

is armed in AWAY Mode. The AWAY

 

indicator also flashes in unison with the

 

STAY indicator when programming

 

various options throughout the

 

Operator’s Manual.

 

See Section 4.2 Arming in AWAY Mode for

 

information on the different methods of

 

arming the system in AWAY Mode.

 

 

Table 3:

AWAY Indicator

 

 

 

 

AWAY

Definition

Indicator

 

On

System is armed in AWAY Mode.

Off

System is not armed in AWAY Mode.

3.3STAY Indicator

The STAY indicator displays that the system is armed in STAY Mode 1 or STAY Mode 2. The STAY indicator also flashes in unison with the AWAY indicator when programming various options throughout the Operator’s Manual. See Section 4.3 Arming in STAY Mode 1 for different methods of arming in STAY Mode 1. See Section 4.4 Arming in STAY Mode 2 to arm in STAY Mode 2.

Table 4: STAY Indicator

STAY

Definition

Indicator

 

On

System is armed in STAY Mode 1

 

or STAY Mode 2.

Off

System is not armed in STAY

 

Mode 1 or STAY Mode 2.

Flashing twice

Zone isolating mode or setting

a second

STAY Mode 2 zones.

Flashing once

Day alarm status – day alarm

every 3 sec.

turned on.

Bosch Security Systems 6/04 920036O.OG.162

Page 6
Image 6