Bosch Appliances DIE 165 R manual Electrical connection, Preparing the ceiling, Electrical data

Models: DIE 165 R

1 48
Download 48 pages 43.69 Kb
Page 13
Image 13
Preparing the ceiling

Prior to installation

Preparing the ceiling

The ceiling must be flat and horizontal.

Ensure that the ceiling is capable of pro- viding a firm hold for mounting screws and plugs. The enclosed plugs are sui- table for concrete and stonework. If the ceiling is made of any other material, use appropriate mounting components.

Weight in kg: 40,5.

We reserve the right to construction changes within the context of technical development.

Electrical connection

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

Earth

Blue

Neutral

Brown

Live

If you fit your own plug, the colours of these wires may not correspond with the identify- ing marks on the plug terminals.

This is what you have to do:

1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( Electrical connection ), or coloured green or green and yellow.

2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured white.

3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured black.

Electrical connection

The extractor hood may be connected to correctly installed earthed sockets only. Preferably attach the earthed sockets directly behind the flue duct.

NOTE:

An additional earthed socket is required for connecting the screen to the power supply.

The earthed socket should be connected via its own circuit.

If the earthed socket is no longer accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector.

If it is necessary to wire the extractor hood directly into the mains:

The extractor hood should only be connected to the electricity supply by a properly qualified electrician.

A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 1/8” and interrupts all poles. Such devices include circuit breakers and contactors.

CAUTION:

If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.

Electrical data:

Are to be found on the name plate inside the appliance after removal of the filter frame.

WARNING: Before undertaking any repairs, always disconnect the extractor hood from the electricity supply.

Length of the connecting cable: 511/8”.

This extractor hood corresponds to EC regulations concerning RF interference suppression.