Remote control installation
Remote control transceiver PCB installation
BPlace the remote control PCB in the back cover of the control unit as shown in Fig. 8.
Fig. 8
B Connect the supplied cable between the main PCB and the
remote control PCB as shown in Fig. 9.
Fig. 9
BReassemble all parts in the reverse order.
5.2Remote control activation
Before the remote
icontrol will work, it must be activated using the
procedure described below with the operator standing in front of the appliance.
BConnect power to heater.
B Press ON / OFF button on the appliance to OFF.