Application Note
Bosch Sensortec
BlueBox
SMB365 (acceleration) and SMD500 (pressure)
•Interrupt functionality, e.g. for theft protection
•Reduced power consumption (20%)
•Reduced acceleration output signal resolution (7 bit)
•Two selectable acceleration ranges: 2g and 10g
•Individual interrupt settings for each axis:
oThreshold (5 bit): 1d = 16LSB (64mg in 2g mode and 0.32g in 10g mode) o Hysteresis (3 bit): 1d = 64LSB (256mg in 2g mode and 1.28g in 10g mode)
•Full selftest capability (see chapter 4.3.4)
20
21
22
26
23
|
|
|
|
| 27 |
| 28 |
| 29 |
|
|
| 30 |
|
| |
24 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25 |
|
|
|
|
|
|
|
|
|
|
| 8 |
|
|
| 9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
How to set up the SMB365 in axis independent interrupt conditions: