Baud Rate

CTFIDSettings Tree Options en 39

Feature

Description

Device

Default

Options

 

 

 

 

 

Baud Rate

The speed at which

G3A Series, ENV Series,

9600

9600, 19200,

 

telecommunicated data is

VG4 Series*

 

38400, 57600

 

transmitted, measured in bytes

 

 

2400*, 4800*,

 

per second (Bps).

 

 

9600*, 19800*,

 

 

 

 

38400*, 57600*

 

 

 

 

 

BiPhase/Audio

Turns BiPhase/Audio on and off.

VG4 Series

BiPhase

BiPhase, Audio

 

(Note: Audio is intended for a

 

 

 

 

VG4 with an Ethernet module.

 

 

 

 

Selecting audio disables Biphase

 

 

 

 

communications.)

 

 

 

 

 

 

 

 

Black Level

The level of the video signal that

Dinion 2X, DinionXF

0

-55 to +55

 

corresponds to the maximum

FlexiDome 2X, UPH Series

 

 

 

limits of the black areas of the

 

 

 

 

picture.

 

 

 

 

 

 

 

 

Blanking

Cuts off the electron beam in a

G3A Series, ENV Series,

Not

Not Blanked,

 

camera pickup device or picture

VG4 Series

Blanked

Blanked

 

tube during the retrace period. It

 

 

 

 

is a signal that is composed of

 

 

 

 

recurrent pulses at line and field

 

 

 

 

frequencies. It is intended

 

 

 

 

primarily to make the retrace on

 

 

 

 

a pickup device or picture tube

 

 

 

 

invisible.

 

 

 

 

 

 

 

 

BLC Level

Electronically compensates for

DinionXF

0

-15 to +15

 

high background lighting to give

Unity, UPH Series

 

 

 

detail that would normally be

 

 

 

 

silhouetted.

 

 

 

 

 

 

 

 

BLC Mode

Toggles the compensation for

UPH Series

Off

On, Off

 

high background lighting to give

 

 

 

 

detail that would normally be

 

 

 

 

silhouetted

 

 

 

 

 

 

 

 

Cable Comp Level

Prevents image degradation

Dinion 2X, DinionXF

(not active)

0 to 15

 

caused by signal losses when

 

 

 

 

transmitting video over long

 

 

 

 

cable lengths.

 

 

 

 

 

 

 

 

Cable Comp Type

Allows you to choose the coax

Dinion 2X, DinionXF

Off

Off, Default,

 

being used. If unknown, select

 

 

RG59,

 

Default. Note: Anything above

 

 

Coax 12, Coax 6

 

1,000 ft. may cause a decrease in

 

 

 

 

picture quality.

 

 

 

 

 

 

 

 

Camera Buttons

Prevents unauthorized change of

Dinion 2X, DinionXF,

Enabled

Enabled,

 

the camera settings by disabling

Dinion,

 

Disabled

 

the buttons.

FlexiDome, FlexiDome 2X,

 

 

 

 

Unity, UPH Series

 

 

 

 

 

 

 

Camera Height

The straight vertical height in

G3A Series, ENV Series,

12 ft.

8 to 100 ft.

 

respect to the surface that you

VG4 500 Series

 

 

 

are tracking.

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc.

User’s Manual

F.01U.141.545 3.09 2009.10