40 en Settings Tree OptionsCTFID

Feature

Description

Device

Default

Options

 

 

 

 

 

Camera ID

16-character camera name that

Dinion 2X, DinionXF

(blank

(blank field)

 

may be displayed according to

FlexiDome 2X, UPH Series

field)

 

 

the ID position.

 

 

 

 

 

 

 

 

Camera ID

Identifies the location of the

Dinion 2X, FlexiDome 2X

Off

Off

Position

camera ID label on the output

 

 

Top Left

 

screen.

 

 

Top Right

 

 

 

 

Bottom Left

 

 

 

 

Bottom Right

 

 

 

 

 

Camera OSD

Enables or disables the camera

G3A Series, ENV Series,

On

On, Off

 

on-screen display information

VG4 Series

 

 

 

from the live video image.

 

 

 

 

 

 

 

 

Color Burst

Off: The color burst in the video

Dinion 2X,

Off

On, Off

 

signal is switched Off in

FlexiDome 2X

 

 

 

monochrome mode.

 

 

 

 

On: The color burst remains

 

 

 

 

active even in monochrome mode

 

 

 

 

(required by some DVRs and IP

 

 

 

 

encoders).

 

 

 

 

 

 

 

 

Custom Tour

Defines the length of time for a

VG4 Series

3 sec.

3-5 sec, 10, 15,

Period

custom camera tour.

 

 

20, 25, 30, 40, 50

 

 

 

 

sec, 1-5 min., 10

 

 

 

 

min.

 

 

 

 

 

Day/Night

Camera is equipped with a

Dinion 2X,

Auto

Auto, Color,

 

motorized IR filter. The

DinionXF LTC 0495,

 

Monochrome

 

mechanical IR filter can be

LTC 0610,

 

 

 

removed in low-light or IR

FlexiDome 495,

 

 

 

illuminated applications by

FlexiDome 2X,

 

 

 

configuration settings.

UnityDome DN VG4-162

 

 

 

 

and VG4-164, DN VG4-152

 

 

 

 

and VG4-154

 

 

 

 

 

 

 

Default Shutter

Allows the shutter speed to be

G3A Series, ENV Series,

1/60

1/60,

 

set to a fast speed to eliminate

Dinion 2X

 

1/100,

 

motion blur and provides

DinionXF,

 

1/120,

 

detailed and clear images of fast-

FlexiDome,

 

1/250,

 

moving objects while there is

FlexiDome 2X,

 

1/500,

 

sufficient light. When light levels

Unity, UPH Series

 

1/1000,

 

fall and other adjustments have

 

 

1/2000,

 

been exhausted, the shutter

 

 

1/5000,

 

speed reverts to the standard

 

 

1/10000

 

setting to maintain sensitivity.

 

 

 

 

 

 

 

 

Digital Zoom

Enables or disables the ability to

G3A Series, ENV Series,

On

On, Off

 

enlarge or reduce the size of an

VG4 Series

 

 

 

image.

 

 

 

 

 

 

 

 

Display Position

Controls the position for the OSD

G3A Series, ENV Series,

0

0 to 16

 

stamping.

VG4 Series

 

 

 

 

 

 

 