Bosch Appliances X20 manual Connecting with a Terminal Program

Models: X20

1 130
Download 130 pages 31.32 Kb
Page 104
Image 104

104 en Operation

VideoJet X20

 

 

Connecting with a Terminal Program

Various requirements must be met in order to operate with a terminal program (see

Section 8.9 Communication with Terminal Program, page 116).

1.Start the terminal program and enter the command 1 in the main menu to switch to the IP menu.

2.Enter the command 4 in the IP menu to change the remote IP address, then enter the IP address of the unit you wish to connect to.

3.Enter the command 0 to return to the main menu and then enter the command 4 to switch to the Rcp+ menu.

4.In the Rcp+ menu, enter the command 5 to activate the automatic connection.

Closing the Connection with a Terminal Program

1.Start the terminal program and enter the command 4 in the main menu to switch to the Rcp+ menu.

2.In the Rcp+ menu, enter the command 5 to deactivate the automatic connection.

DOC V4.0 2009.06

Installation and Operating Manual