5-2. Amperage Adjustment Controls

60 Hz Model Shown

1

2

Control can be adjusted while welding.

1Remote Amperage Control Switch

For front panel control of a module, place switch on that module in Off position.

For remote control, place switch in On position. See Example below.

2 Amperage Adjustment Control

Use control at each module to select weld amperage for that mod- ule. The numbers are weld amperes.

3 Remote Hand Control

Example Of Combination Remote Amperage Control

3

Min (35 A)

Max (125 A)

Set Switch

 

Set Desired Maximum Amperage

 

Adjust Remote Control

 

 

 

 

Ref. ST-174 143

5-3. Power Switch Push Buttons And Pilot Light

1

2

3

1Pilot Light

2Power On Push Button

Press button to turn unit, pilot light, and fan motors On.

3 Power Off Push Button

Press button to turn unit, pilot light, and fan motors Off.