4-9. 115 Volts AC Duplex Receptacle

115V AC 115V AC OVERLOAD

10A BREAKER

CLOSED

OPEN

1115 Volts AC Duplex Receptacle RC2

This receptacle supplies up to 10 amperes of 115 volts ac power.

The duplex receptacle is protected from overload by supplementary protector CB1 (see Section 6-2).

1

Ref. ST-144 570-A / Ref. SC-085 382

 

4-10. Connecting Input Power

A. Positioning Jumper Links

Y Turn Off polyweld system, and disconnect input power before inspecting or installing.

1

1

2

230 VOLTS

TE3 TE2

460 VOLTS

575 VOLTS

TE3

TE2

TE3

TE2

S-006 233-A

Tools Needed:

3/8, 1/2 in

Jumper links allow operation on differ- ent input voltages and are factory set for the highest input voltage.

Check input voltage available at site.

Open rear panel access door to check jumper links.

1 Input Voltage Label

Look at jumper links and compare link position with unit label. Only one label will be on unit.

2 Input Voltage Jumper Links

Move links to match input voltage. For example, use 230 volts position when 230 volts input power is available.

Close rear panel access door or go on to Section 4-10B.

ssb5.1* 2/92 − Ref. ST-144 569-B

OM-218 Page 18

Page 22
Image 22
Miller Electric MARK VIII-2 manual Volts AC Duplex Receptacle, Connecting Input Power, Positioning Jumper Links, TE3 TE2