SECTION 6 − MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

Y Turn Off polyweld system, and disconnect input power before inspecting, maintaining, or servicing.

 

3 Months

 

Clean

 

And

See

Tighten

Section

Weld

4-6

Terminals

 

Tape Or

 

Replace

 

Cracked

− −

Cables

 

 

Replace

 

Unreadable

10

Labels

 

6 Months

Blow Out

OROr

Vacuum

Inside

 

During Heavy Service,

− −

Clean Monthly

 

Fan

 

Motor

 

Sealed

 

Bearings

 

− No Oil

− −

Needed

 

ST-144 567-A

6-2. Overload Protection

A. Overload Supplementary Protector CB1 And Module Supplementary Protectors CB11 Through CB81

YTurn Off polyweld system, and dis- connect input power before inspect- ing, maintaining, or servicing.

2

1Overload Supplementary Protecotr CB1

Supplementary protector CB1 pro- tects the 115 volts ac windings of control transformer T3 from over- load. If CB1 opens, the 115 volts ac duplex receptacle RC2 would not work. Manually reset CB1.

2Module Supplementary Protectors CB11 Through CB81

The control circuitry in each of the eight modules is protected from overload by a supplementary pro- tector CBX1 (“X” represents the number of the applicable module, 1−8). If a module supplementary protector opens, output from the affected module would drop to mini- mum and can not be regulated. Manually reset the affected protector.

115V AC 115V AC OVERLOAD

10A BREAKER

CLOSED

OPEN

1ST-144 570-A / Ref. ST-174 143 / Ref. SC-085 382