*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
the mm2 equivalent weld cable sizes.S-0008-C
OM-218 Page 13

4-4. Weld Cable Size

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 ft Or Less

100 ft

150 ft

 

200 ft

250 ft

300 ft

 

350 ft

400 ft

 

(15m)

(30m)

(45 m)

 

(60 m)

(70 m)

(90 m)

 

(105 m)

(120 m)

Welding

 

 

 

 

 

 

 

 

 

 

 

 

 

10 Thru 100% Duty Cycle

 

 

 

 

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

4

 

3

2

1

 

1/0

1/0

150

3

3

2

 

1

1/0

2/0

 

3/0

3/0

200

2

2

1

 

1/0

2/0

3/0

 

4/0

4/0

250

1

1

1/0

 

2/0

3/0

4/0

 

2-2/0

2-2/0

300

1/0

1/0

2/0

 

3/0

4/0

2-2/0

 

2-3/0

2-3/0

350

2/0

2/0

3/0

 

4/0

2-2/0

2-3/0

 

2-3/0

2-4/0

400

2/0

2/0

3/0

 

4/0

2-2/0

2-3/0

 

2-4/0

2-4/0

500

4/0

4/0

4/0

 

2-2/0

2-3/0

2-4/0

 

1000

1000

600

4/0

4/0

2-2/0

 

2-3/0

2-4/0

1000

 

1000

2-750

700

4/0

2-2/0

2-3/0

 

2-4/0

1000

1000

 

2-750

2-750

800

2-2/0

2-2/0

2-3/0

 

2-4/0

1000

2-750

 

2-750

2-1000

900

2-3/0

2-3/0

2-4/0

 

1000

1000

2-750

 

2-1000

2-1000

1000

2-3/0

2-3/0

2-4/0

 

1000

2-7500

2-750

 

2-1000

2-1000

1250

2-4/0

2-4/0

750

 

2-750

2-750

2-1000

 

2-1000

 

1500

500

750

1000

 

2-750

2-1000

2-1000

 

 

 

1750

750

1000

2-750

 

2-1000

2-1000

 

 

 

 

2000

750

1000

2-750

 

2-1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 17
Image 17
Miller Electric MARK VIII-2 Weld Cable Size, 150 ft 200 ft 250 ft, 350 ft 400 ft 15m 30m 45 m 60 m 70 m 90 m 105 m 120 m