44
Chapter 4. Changing the settings of a sample

Procedure

1. Press the pad of the sample whose settings you want to
change.
2. Press [WAVE EDIT].
fig.04-01a
3. Use CURSOR [] [] to select the setting (parameter)
that you want to change.
4. Use the VALUE dial to change the value of the setting.
If you want to change the settings of another sample in
the same pad bank, press the pad for that sample, and
repeat steps 3 and 4.
If you want to change the settings of a sample in another
pad bank, switch to that pad bank (p. 30), press the pad
for the sample you want to edit, and repeat steps 3 and 4.
5. Press [EXIT], [SONG], or [PTN] to return to the Play
screen.
Never turn off the power while the display indicates
Keep Power On!

Adjusting the volume of a

sample

To adjust the volume of a sample, select Level in step 3 of
Procedure on p. 44.

Level 0127

This adjusts the volume.

Adjusting the stereo position

of a sample
To adjust the stereo position of a sample, select Panpot in
step 3 of Procedure on p. 44.

Panpot LEFT, CENTER, RIGHT

LEFT: Pan the sound to OUTPUT L.
CENTER: Pan the sound to the center.
RIGHT: Pan the sound to OUTPUT R.
* Panpot has no effect for samples that were sampled with a
Type of STEREO.

Changing how a sample

plays and stops

To change how a sample plays and stops when you press a
pad, select Pad Play in step 3 of Procedure.

Pad Play TRIG, GATE, DRUM

TRIG: The sample will start playing when you press the pad,
and will stop when you press the pad once again.
GATE: The sample will play only while you continue
holding down the pad.
DRUM: When you press the pad, the sample will play
once, and will stop at the End point.
* If you select DRUM, the Loop Mode setting has no effect.

Looping the playback of a

sample

If you want a sample to loop (play back repeatedly), select
Loop Mode in step 3 of Procedure.

Loop Mode ON, OFF

ON: The sample will loop (play back repeatedly).
OFF: The sample will not loop.