JAM CLEARING PROCEDURE

Disconnect tool from air supply before making adjustments or before attempting any part assembly or disassembly.

On occasion nails can jam in the nose of a pneumatic nailer. This can be caused by striking a metal plate in the wall, drywall screw, or some other hard object. The BT1855 and SX1838 feature open drive channel architecture for jam clearing. To clear a jam follow this procedure:

1.Disconnect the tool from the air supply.

2.Open the magazine by depressing the magazine release button and pulling open the magazine.

3.Remove the jam fastener. In certain circumstances, pliers may be required to remove the fastener.

4.Close the magazine.

BT1855 JAM CLEARING

SX1838 JAM CLEARING

-12-

Page 12
Image 12
Bostitch BT1855K manual JAM Clearing Procedure, BT1855 JAM Clearing SX1838 JAM Clearing