JAM CLEARING PROCEDURE
Disconnect tool from air supply before making adjustments or before attempting any
partassembly or disassembly.
Onoccasion nails can jam in the nose of a pneumatic nailer. This can be caused by striking a metal plate
inthe wall, drywall screw, or some other hard object. The BT1855 and SX1838 feature open drive channel
architecturefor jam clearing. To clear a jam follow this procedure:
1.Disconnect the tool from the air supply.
2.Open the magazine by depressing the magazine release button and pulling open the magazine.
3.Remove the jam fastener. In certain circumstances, pliers may be required to remove the fastener.
4.Close the magazine.
BT1855 JAM CLEARING
SX1838 JAM CLEARING
-12-