TROUBLESHOOTING

PROBLEM

Trigger valve housing leaks air

Trigger valve stem leaks air

Frame/nose leaks air

Frame/cap leaks air

Failure to cycle

Lack of power; slow to cycle

Skipping fasteners; intermittent feed

Fasteners jam in tool

CAUSECORRECTION

O-ring cut or cracked . . . . . . . . . . . . . . . . . . . .Replace O-ring

O-ring/seals cut or cracked . . . . . . . . . . . . . .Replace trigger valve assembly

O-ring or gasket is cut or cracked . . . . . . . . .Replace O-ring or gasket

Bumper cracked/worn . . . . . . . . . . . . . . . . . . .Replace bumper

Damaged gasket or seal . . . . . . . . . . . . . . . . .Replace gasket or seal

Cracked/worn head valve . . . . . . . . . . . . . . .Replace head valve

Loose cap screws . . . . . . . . . . . . . . . . . . . . . . .Tighten and recheck

Air supply restriction . . . . . . . . . . . . . . . . . . . .Check air supply equipment Worn head valve . . . . . . . . . . . . . . . . . . . . . . .Replace head valve Broken cylinder cap spring . . . . . . . . . . . . . . .Replace cylinder cap spring Head valve stuck in cap . . . . . . . . . . . . . . . . . .Disassemble / Check / Lubricate

Broken cylinder cap spring

.Replace cap spring

Rings/seals cut or cracked

.Replace rings/seals

Exhaust blocked

.Check bumper, head valve spring

Trigger assembly worn/leaks

.Replace trigger assembly

Dirt/tar build up on driver

.Disassemble nose/driver to clean

Cylinder sleeve not seated correctly

 

on bottom bumper

.Disassemble to correct

Air pressure too low

.Check air supply equipment

Clogged air filter

.Clean or replace air filter

Worn bumper

.Replace bumper

Tar/dirt in driver channel

.Disassemble and clean nose and driver

Air restriction/inadequate air flow through

 

quick disconnect socket and plug

.Replace quick disconnect fittings

Worn piston ring

.Replace ring, check driver

Damaged pusher spring

.Replace spring

Low air pressure

.Check air supply system to tool

Loose magazine nose screws

.Tighten all screws

Fasteners too short for tool

.Use only recommended fasteners

Bent fasteners

.Discontinue using these fasteners

Wrong size fasteners

.Use only recommended fasteners

Leaking head cap gasket

.Tighten screws/replace gasket

Trigger valve O-ring cut/worn

.Replace O-ring

Broken/chipped driver

.Replace driver (check piston ring)

Dry/dirty magazine

.Clean/lubricate use BOSTITCH Air Tool Lubricant

Worn magazine

.Replace magazine

Clogged air filter

.Clean or replace air filter

Driver channel worn . . . . . . . . . . . . . . . . . . . . .Replace nose/check door

Wrong size fasteners . . . . . . . . . . . . . . . . . . . .Use only recommended fasteners Bent fasteners . . . . . . . . . . . . . . . . . . . . . . . . . .Discontinue using these fasteners Loose magazine/nose screws . . . . . . . . . . . .Tighten all screws Broken/chipped driver . . . . . . . . . . . . . . . . . . .Replace driver

-15-

Page 15
Image 15
Bostitch BT1855K manual Troubleshooting, Problem, Causecorrection