Figure 19

LF Contour

HF Contour

Figure 20

C1

C2

C3

C7

C8

C9

C13

C14

T1

T2

T3

C4

C5

C6

C10

C11

C12

S1

S2

S3

S4

Description of Controls

Description of controls

The unit features a comprehensive set of controls to tune the performance of each speaker according to the conditions of use. The response may be shaped by a combination of three parametric equalisers, each having a level range of +4.5 / -12 dB, and low- and high-frequency contour controls, the effects of which are illustrated in figure 19. In addition, level controls are provided to compensate for any differences in gain between both the subwoofer and LF power amplifiers compared to the MF/HF power amplifier.

To access the front of the unit, pull off the decorative facing plate.

Refer to figure 20 for the layout of the inputs and controls, which have the following functions:

T1

Test input socket (unbalanced)

To connect external signal generator

T2

Test input socket (balanced)

To connect external signal generator

T3

Output level indicator lights

To balance levels

C1

Low-frequency contour control

± 6dB see figure 19 top graph

C2

High-frequency contour control

± 4dB see figure 19 bottom graph

C3

Parametric filters-overall gain

 

C4

Parametric filter 1-gain

+4 / -12dB

C5

Parametric filter 1-Q

0.5 - 5

C6

Parametric filter 1-frequency

30Hz - 500Hz

C7

Parametric filter 2-gain

+4 / -12dB

C8

Parametric filter 2-Q

0.5 - 5

C9

Parametric filter 2-frequency

30Hz - 500Hz

C10

Parametric filter 3-gain

+4 / -12dB

C11

Parametric filter 3-Q

0.5 - 5

C12

Parametric filter 3-frequency

30Hz - 500Hz

C13

LF output gain

 

C14

Subwoofer output gain

 

S1

DIP switch bank 1

See table

S2

DIP switch bank 2

See table

S3

DIP switch bank 3

See table

S4

DIP switch bank 4

See table

17

Page 18
Image 18
Bowers & Wilkins CT800 installation manual Description of Controls, Description of controls