Figure 7. Water Heater Piping — Multiple Heaters, Multiple Tanks.

Internet Version for Reference Only

Copper Brute II

Page 17

 

 

 

 

LOCATION OF

FACTORY-MOUNTED 5

PUMP

5

CAUTION: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND VALVING, CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS.

LEGEND

 

 

THERMOMETER

 

EXPANSION TANK

 

 

TEMPERATURE

TPRV

 

SENSOR

 

 

GLOBE VALVE

PRV

3-WAY VALVE

CHECK VALVE

 

VALVE

PRESSURE REDUCING

PUMP

VALVE

 

KEY:

WATER CATEGORY

GRAIN HARDNESS PER GALLON

S = SOFT

1 THROUGH 7.5

N = NORMAL

7.6 THROUGH 17

H = HARD

OVER 17

PPM / 17.1 = Grains Per Gallon

6

4

3

 

CWMU

1

.

 

 

 

RECIRC

 

 

2

Y

SUPPL

2

NOTES:

1.OPTIONAL CWMU & RECIRC. LINE LOCATION.

2.LOCATE PENNANT DHW SENSOR OR REMOTE AQUASTAT WELL IN LOWER 1/3 OF TANK.

3.BACK FLOW PREVENTER MAY BE REQUIRED. CHECK LOCAL CODES.

4.THERMAL EXPANSION TANK MAY BE REQUIRED. CHECK LOCAL CODES.

5.WHEN USING FACTORY MOUNTED PUMP, MAX PIPE LENGTH IS 30 FEET TOTAL, SIX 90° ELBOWS , FULL PIPE SIZE.

6.COMMON PIPING, SHOWN WITH HEAVY LINES, MUST BE SIZED FOR MAXIMUM COMBINED HEATER FLOW RATE.

7.CAUTION: PUMP SIZING MUST BE BASED UPON WATER HARDNESS AT JOB SITE

8.MINIMUM INLET WATER TEMPERATURE IS 120°F.

Figure 7. Water Heater Piping — Multiple Heaters, Multiple Tanks.

Page 17
Image 17
Bradford-White Corp BWCV warranty Internet Version for Reference Only, Copper Brute, Page