HIGH INPUT DIRECT VENT INSTALLATION & OPERATING INSTRUCTION MANUAL
Internet Version for Reference Only
FOR YOUR SAFETY
DIRECT VENT GAS WATER HEATER
CONGRATULATIONS
Internet Version for Reference Only
INSTALLATION
TABLE OF CONTENTS
PARTS LIST DRAWINGS
INSTALLATIONS FOR POTABLE WATER AND SPACE
DANGER
GENERAL INFORMATION
Internet Version for Reference Only
Internet Version for Reference Only
INSTALLATION
CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
Installation Locating The Water Heater continued
COVERED BY THE WARRANTY. DO NOT OPERATE THE WATER
Internet Version for Reference Only
HEATER CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT
Most people recognize this odor as a “sulfur” or “rotten egg” smell
Internet Version for Reference Only
Internet Version for Reference Only
Installation continued
MINIMUM CLEARANCES
OPTIONAL DIRECT VENT-AIR INTAKE TERMINAL GUARD
Internet Version for Reference Only
Installation Minimum Clearances continued
Figure 1A
Internet Version for Reference Only
Installation Minimum Clearances continued
Figure 1B
Internet Version for Reference Only
Installation Minimum Clearances continued
Contact the manufacturer of the water heater for replacement parts
DO NOT install any damaged vent-air intake system components
Internet Version for Reference Only
VENTING
Internet Version for Reference Only
Installation Venting continued
HORIZONTAL AND VERTICAL VENT-AIR INTAKE LENGTHS
Internet Version for Reference Only
Table A
Internet Version for Reference Only
no addl
order
Internet Version for Reference Only
Contact the manufacturer of the water heater for replacement parts
Do not install any damaged vent-air intake system components
Internet Version for Reference Only
Tape Measure Drill
See Figure
Internet Version for Reference Only
Internet Version for Reference Only
7. Extend the four 4 inch 10.2 cm diameter telescopic tube to its maximum length and slide the backing plate over it. Place the large end of the four 4 inch 10.2 cm diameter telescopic tube through the hole in the outside wall. Insert the smaller end of the four 4 inch diameter 10.2 cm telescopic tube into the flared end of the four 4 inch 10.2 cm diameter elbow, one 1 inch 2.5 cm or until seated. Drill three
Internet Version for Reference Only
Internet Version for Reference Only
8. Extend the six 6 inch 15.2 cm diameter telescopic tube to its maximum length. Place the large end of the six 6 inch 15.2 cm diameter telescopic tube over the collar on the outer wall mounting plate. Drill three 3 1/8 inch 3.2 mm diameter holes, 120o apart, through the six 6 inch 15.2 cm diameter telescopic tube into the collar on the outer wall mounting plate. Fasten with three 3 #8 sheet metal screws supplied. Using the supplied special RTV silicone sealant, apply a sufficient amount to seal the joint See Figure
9. From outside the building, slide the six 6 inch 15.2 cm diameter telescopic tube through the opening in the wall until the outer wall mounting plate is flush with the wall See Figure
Internet Version for Reference Only
Internet Version for Reference Only
11. From inside the building, slide the backing plate over the six 6 inch 15.2 cm diameter telescopic tube until it is flush with the wall. Adjust the length of the six 6 inch 15.2 cm diameter telescopic tube and insert the end into the flared end of the six 6 inch 15.2 cm diameter elbow one 1 inch 2.5 cm or until seated. Drill three 3 1/8 inch 3.2 mm diameter holes, 120o apart, through the six 6 inch 15.2 cm diameter elbow into the six 6 inch 15.2 cm diameter telescopic tube and through the tubes where the small and large sections overlap. Fasten with three 3 #8 sheet metal screws supplied. Using the supplied special RTV silicone sealant, apply a sufficient amount to seal all joints See Figure
Internet Version for Reference Only
Internet Version for Reference Only
Note BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
WATER CONNECTIONS
MAIN WATER SUPPLY VALVE
Internet Version for Reference Only
Installation Water Connections continued
TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE
FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4”
FROM EXCESSIVE TEMPERATURES AND PRESSURES
Internet Version for Reference Only
Internet Version for Reference Only
Installation Water Connections continued
Internet Version for Reference Only
OPEN FLAME FOR TESTING
Internet Version for Reference Only
GENERAL OPERATION
CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
WARNING If you do not follow these instructions exactly, a fire or
Internet Version for Reference Only
Internet Version for Reference Only
THERMOSTAT ADJUSTMENT
DANGER
Internet Version for Reference Only
Burner Flame Check
Internet Version for Reference Only
MAINTENANCE
CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
Internet Version for Reference Only
Maintenance continued
WARNING! THIS WATER MAY BE HOT
Internet Version for Reference Only
READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH
OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED
Internet Version for Reference Only
PARTS LIST
Certain Models
Optional Not Shown
DIRECT VENT WATER HEATER
Internet Version for Reference Only
VENT-AIR INTAKE KITS
Internet Version for Reference Only
Internet Version for Reference Only
THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF GAS WATER HEATERS
SUITABLE FOR WATER POTABLE HEATING AND SPACE HEATING