SERVICE PROCEDURE AG-III

Honeywell Gas Control and Thermowell

Replacement

HONEYWELL GAS CONTROL ASSEMBLY TO THERMALWELL

Step 1. Install threaded end of thermowell into water heater. When tight, be sure thermowell flange is positioned so that thermowell relief opening is in the 6 o’clock position for proper control alignment (see Figure 35).

Thermowell flange slots

Route wire through

6 o’clock position

relief opening

Figure 35

Step 2. Route lead wires through the relief opening (see Figure 35).

Step 3. Align slots located on the thermowell flange with tabs located on the back of the gas control (see Figure 36).

Gas control tabs

Figure 36

Step 4. Carefully push the gas control back onto the thermowell flange.

Step 5. Install burner assembly and reconnect pilot tubing and main burner feed line to gas control.

Step 6. Reconnect wire harness and igniter wire to the gas control.

Step 7. Resume water supply to water heater and check for leaks. Be sure tank is full of water.

Step 8. Reconnect the gas supply to gas control. Check for gas leaks using a soapy water solution.

Step 9. To resume operation follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Page 19

19

Page 19
Image 19
Bradford-White Corp C(S, D)W275T*(BN, CX service manual Honeywell GAS Control Assembly to Thermalwell