SERVICE PROCEDURE AG-III

Honeywell Thermowell Testing and

Replacemet

HONEYWELL THERMOWELL TESTING

Step 1. If gas control has gone into lockout due to excessive tank temperature (four flashes and a three second pause) reset the gas control to the “OFF” position. Then follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Step 2. Observe the water heater operation. If the gas control continues to lockout due to excessive tank temperature proceed to Step 3, thermowell testing, to determine the cause.

Step 3. To perform thermowell testing turn the gas control to the “OFF” position and disconnect the thermowell harness from the gas control.

Disconnect

thermowell wire

harness

Figure 28

 

Figure 29

CAUTION

DO NOT Use standard multimeter probes to test. Doing so will damage connector. Use special pin type electronic probes or small diameter wire pins inserted into connector

Figure 30

Step 4. Using a multimeter set to measure Ohms determine the resistance of the thermowell sensor (See caution on this page).

Step 5. Hold one probe in the center pin and measure the outside positions pins (see figure 29 & 30).

Step 6. Refer to Table 1 on page 17 to determine the correct resistance value for the water heater tank temperature.

Step 7. If the resistance values are correct the gas control needs to be replaced. If they are incorrect the thermowell needs to be replaced.