SERVICE PROCEDURE AG-III

Gas Control Testing and Replacement

For Models using White Rodgers or

Robertshaw Gas Control

ECO (Energy Cut Off) TESTING

Step 1. Disconnect thermocouple from gas control.

Step 2.

Using a multimeter capable of measuring Ohms (or continuity),

 

 

 

attach one lead (alligator clip) to the pilot tube. Insert the other lead

 

 

 

(probe) fully into the magnet opening, Be sure the probe makes

 

 

 

contact only at the top center of the magnet opening. Do not allow

Figure 23

 

 

the probe to make contact with the threaded sides of the opening.

 

 

 

Step 3.

If continuity is indicated, the ECO is OK. If continuity is not indicated, the ECO has opened and the

 

gas control must be replaced.

 

 

GAS CONTROL REPLACEMENT

Step 1. Rotate knob of the gas control

to the “OFF” position.

Step 2. Turn off gas supply to water heater.

Step 3. Disconnect gas supply line from gas control.

Step 4. Turn off water supply and drain water heater completely.

Step 5. Remove outer jacket burner access door.

Step 6. Slide open inner combustion chamber door.

For White Rodgers gas control, depress knob slightly and rotate clockwise to the “OFF” position.

Figure 24

For Robertshaw gas control, rotate knob clockwise to the “OFF” position.

Figure 25

Figure 26