Furuno RC-1500-1T manual Self Tests, Self test at power application communication unit

Models: RC-1500-1T

1 418
Download 418 pages 48.34 Kb
Page 383
Image 383

Self Tests

The communication unit and the terminal unit are equipped with self tests which check them for proper operation.

Self test at power application (communication unit)

The communication unit performs the following tests when it is turned on:

a)ROM sum test

b)RAM read and write test

c)DP RAM read and write test

d)EEPROM sum test

e)VITERBI decoder test

If the unit finds no fault it goes into normal operation.

Testing the communication unit through the keyboard

This test can only be initiated from the main DTE. The communica- tion unit must be idle.

1.Press [F7] to display the Options menu.

2.Press [6] to display the Test menu.

3.Press [3]. The Communication Unit (self test) screen appears.

Figure 8-1 Communication unit screen

4.Press [Enter] to start the test.

The message “Now Communication Unit-testing” appears in blinking reverse video during testing.

8-3

Page 383
Image 383
Furuno RC-1500-1T manual Self Tests, Self test at power application communication unit, 1 Communication unit screen