8. CHECKING, MAINTENANCE

WARNING

Do not open the equipment.

Hazardous voltage which can cause electrical shock exists inside the equipment. Only qualified personnel should work inside the equipment.

8.1Daily Test

Authorities require that the equipment be checked daily for proper operation to ensure that it will function properly in the event of distress. Execute the daily test as below.

1.At the DSC standby screen or radiotelephone setting screen, press the [3/TEST] key to start the test.

2.After several seconds the test results appear followed by the audio alarm. OK denotes normal operation, and NG (No Good), error. For NG (No Good) contact your dealer for advice.

**DSC-60 daily test **

MAIN CPU:

ROM/RAM test executed and version no. displayed.

MODEM:

DSP ROM and DSC signal loopback tests executed and

JAN-01-2000-15:24

 

version no. displayed.

MAIN CPU

: OK VER.XX*

RCVR1:

Distress/safety watch received tested.

MODEM

: OK VER.XX*

RCVR2:

Routine watch receiver (option) tested.

RCVR1

: OK

REMOTE RT:

CAID of MIF command sent and received. Name of

 

equipment connected (if FURUNO make) and result appear.

RCVR2

: OK

 

 

(System setting RP PORT must be set for RT or MIF otherwise

REMOTE RT

: OK FS1562

 

 

nothing appears.)

REMOTE DP

: OK DP-6

 

REMOTE DP:

CAID of MIF command sent and received. Name of

 

 

 

 

 

equipment connected (if FURUNO make) and result appear.

 

 

 

(Nothing appears when system setting NBDP PORT is OFF.)

 

 

Alarm:

Distress alarm sounds for two seconds after completion

 

 

 

of test.

* XX = Version number

8-1